OM-485 Page 15
4-5.
Selecting Weld Cable Sizes
Total Cable (Copper) Length In Weld Circuit Not Exceeding
Welding
Amperes
100 ft (30 m) Or Less
150 ft
(45 m)
200 ft
(60 m)
250 ft
(70 m)
300 ft
(90 m)
350 ft
(105 m)
400 ft
(120 m)
Amperes
10 – 60%
Duty Cycle
60 – 100% Duty
Cycle
10 – 100% Duty Cycle
100
4
4
4
3
2
1
1/0
1/0
150
3
3
2
1
1/0
2/0
3/0
3/0
200
3
2
1
1/0
2/0
3/0
4/0
4/0
250
2
1
1/0
2/0
3/0
4/0
2-2/0
2-2/0
300
1
1/0
2/0
3/0
4/0
2-2/0
2-3/0
2-3/0
350
1/0
2/0
3/0
4/0
2-2/0
2-3/0
2-3/0
2-4/0
*Weld cable size (AWG) is based on either a 4 volts or less drop or a current density of at least 300 circular mils per ampere. Contact your
distributor for the mm
2
equivalent weld cable sizes.
S-0007-E
4-6.
Remote 14 Receptacle Information
Socket*
Socket Information
24 VOLTS AC
A
24 volts ac.
A
J
B
K
I
L
N
H
24 VOLTS AC
B
Contact closure to A completes 24 volt ac contac-
tor control circuit.
C
L
N
H
D
M
G
115 VOLTS AC
I
115 volts ac.
E
F
115 VOLTS AC
J
Contact closure to I completes 115 volt ac contac-
tor control circuit.
C
0 to +10 volts dc output to remote control.
A/V
D
Remote control circuit common.
AMPERAGE
VOLTAGE
E
0 to +10 volts dc input command signal from
remote control.
G
Circuit common for 24 and 115 volt ac circuits.
ST-801 534
GND
K
Chassis common.
*The remaining sockets are not used.