A complete Parts List is available at www.MillerWelds.com
OM-264259 Page 31
7-3. Remote Control Cable Functions
Function
Lead
Socket
Lead Information
Remote Start
White
1
White and red leads connect to a set of customer-supplied remote contacts to
provide a remote trigger input signal to RC61 sockets 1 and 5 for the remote
start function.
Red
5
Noise Suppression
Shielding
3
Chassis ground.
7-4. Remote Voltage Sense Connection
Ref. 804 041-A / 243 336-A
!
Turn off power source and
disconnect input power.
Remove wrapper (see Section 8-4).
Remote voltage sense is an arc
voltage output signal for automatic
torch height adjustment.
1
Snap-in Blank
2
Secondary Interconnect
Board PC4
3
Receptacle RC48
Remove snap-in blank from rear
panel.
Route plug end of cable through
opening in rear panel.
Route plug end of cable over to
PC4.
Allowing adequate slack inside the
machine, secure cable and strain
relief by snapping strain relief into
opening in rear panel.
Connect plug to RC48 on PC4.
Install wrapper on unit.
Cut off crimped terminals on lead
ends, and connect lead 1 to +volts
DC (work) and lead 2 to
−
volts DC
(electrode) on customer-supplied
voltage sense device.
3
2
1
Tools Needed:
Torx 25
Содержание Spectrum 875 Auto-Line
Страница 45: ...OM 264259 Page 41 Notes...
Страница 46: ...OM 264259 Page 42 SECTION 9 ELECTRICAL DIAGRAM Figure 9 1 Circuit Diagram For Hand Held Torch Applications...
Страница 47: ...OM 264259 Page 43 234 157 B...
Страница 48: ...OM 264259 Page 44 Figure 9 2 Circuit Diagram For Machine Torch Applications...
Страница 49: ...OM 264259 Page 45 265 998 A...