.
A complete Parts List is available at www.MillerWelds.com
OM-272989 Page 34
6-5. Internal Motor 24 Inch Calibration (Menu 1 Of 10)
.
The unit’s internal drive motor is calibrated
at the factory. No calibration is needed un-
less drive motor or control board is
changed.
1
Wire/Rod/Tungsten Minus (
−
) Button
2
Material Thickness Plus (+) Button
3
Material Thickness Minus (
−
) Button
4
Left Adjustment Knob
5
Right Adjustment Knob
Cut wire flush at nozzle.
Follow instructions in Section 6-4 to enter the
setup menu.
To perform a motor calibration 24 in. run-out
test at 100 IPM, turn left Adjustment knob, and
verify that a check mark appears next to 100
IPM. Wait for the lock symbol to change from
unlocked to locked.
Be sure wire is cut flush at nozzle, then trigger
the MIG gun. Motor will feed approximately 24
in. of wire through gun.
Cut wire flush at nozzle and measure run-out.
If length of run-out is not 24 in., turn left Adjust-
ment knob to increase/decrease length of
run-out.
Wait for lock symbol to change from unlocked
to locked and repeat test.
To perform a motor calibration 24 in. run-out
test at 500 IPM, turn right Adjustment knob,
and verify that a check mark appears next to
500 IPM.
Wait for the lock symbol to change from un-
locked to locked.
Be sure wire is cut flush at nozzle, then trigger
the MIG gun. Motor will feed approximately 24
in. of wire through gun.
Cut wire flush at nozzle and measure run-out.
If length of run-out is not 24 in., turn right Ad-
justment knob to increase/decrease length of
run-out.
Wait for lock symbol to change from unlocked
to locked and repeat test.
To exit menu, simultaneously press and re-
lease the Wire/Rod/Tungsten Minus (
−
) button
and Material Thickness Plus (+) button, or turn
unit off and on.
Ref. 271491A
1
3
2
4
5
6-6. Internal Motor Run-In Speed (Menu 2 Of 10)
1
Wire/Rod/Tungsten Minus (
−
)
Button
2
Auto-Set Button
3
Material Thickness Plus (+)
Button
Follow instructions in Section 6-4 to
enter the setup menu.
To change the run
−
in setting, press
the Auto
−
Set button.
Run
−
in is the wire speed prior to the
welding arc being struck. When set
to Automatic, the welder deter-
mines the optimal run
−
in speed for
each start. When set to disabled,
the run
−
in speed is the same as the
weld wire speed.
To exit the menu, simultaneously
press and release the Wire/Rod/
Tungsten Minus(
−
) button and Ma-
terial Thickness Plus (+) button, or
turn unit off and on.
Ref. 271491A
1
2
3
Содержание Multimatic 215
Страница 49: ...OM 272989 Page 45 Notes...
Страница 50: ...OM 272989 Page 46 SECTION 8 ELECTRICAL DIAGRAM Figure 8 1 Circuit Diagram...
Страница 51: ...OM 272989 Page 47 272984 A...