OM-708 Page 8
SECTION 4 – OPERATION
4-1.
Controls
ST-146 013-A
1
Spot Weld Timer And Pilot
Light
Weld time adjusts from 0 to 5
seconds. The pilot light turns on
when the weld cycle begins and off
when the cycle ends.
2
Hand Lever
Use lever to open and close tongs.
Close the hand lever during the
welding process to compress the
material between the tips. To adjust
tong pressure, see Section 3-3.
3
Start Switch
Move start switch sideways in ei-
ther direction to start weld cycle.
When weld cycle time ends, or the
start switch is released, weld output
stops, and the timer resets for
another weld cycle.
4
Power Switch
4
1
2
3
SECTION 5 – MAINTENANCE AND TROUBLESHOOTING
5-1.
Routine Maintenance
Y
Disconnect power before maintaining.
Every Use
3 Months
6 Months
Inspect
Tips
Replace
Unreadable
Labels
Blow Off
Or
Vacuum
Unit
During Heavy Service,
Clean Monthly
OR