OM-235 241 Page 12
4-4.
Rear Panel Receptacle Information
956.142.656
!
Turn off power before making
connections.
!
Do not use worn, damaged, un-
dersized, or repaired cables.
1
Coolant Out Connection
Connect coolant return hose to coolant
out fitting.
2
Coolant In Connection
Connect coolant supply hose to
coolant in fitting.
3
Gas Input Connector
Connect gas supply hose to gas input
fitting (see Section 4-2).
4
115 V Input Power Cord
5
14-Pin Receptacle
Make connections between recept-
acle and matching receptacle on weld-
ing power source.
6
Positive (+) Input Receptacle
Connect cable from positive weld out-
put terminal of welding power source.
7
Negative (−) Input Receptacle
Connect cable from negative weld out-
put terminal of welding power source.
8
Supplementary Protector CB1
CB1 protects unit from overload.
1
2
3
5
6
7
4
8
4-5.
Front Panel Receptacle Information
956.142.656
!
Turn off power before making con-
nections.
!
Do not use worn, damaged, under-
sized, or repaired cables.
1
On/Off Switch
Use switch to turn unit on and off.
2
Remote 14-Pin Receptacle
Make connections according to Section 4-3.
3
Coolant In Connection
Connect torch return hose to coolant in fitting.
4
Coolant Out Connection
Connect torch supply hose to coolant out fit-
ting.
5
Gas Out Connection (See Section 4-2)
Connect torch supply hose to gas out fitting.
6
Negative (−) Output Receptacle
Connect TIG torch when TIG welding, or
work cable when Stick welding.
7
Positive (+) Output Receptacle
Connect work cable when TIG welding, or
electrode holder when Stick welding.
1
2
3
4
5
6
7