OM-235 241 Page 8
SECTION 3 − SPECIFICATIONS
3-1. Serial Number And Rating Label Location
The serial number and rating information for this product is located on the rear panel. Use rating label to determine input power requirements and/or
rated output. For future reference, write serial number in space provided on cover of this manual.
3-2.
Specifications
Type Of Input
Power
Welding Power Source
Type
Welding
Voltage
Range
Welding
Current
Range
Rated Welding Output
Overall Dimensions
Weight
115 Volts AC
Single-Phase
500mA
50/60 Hz
XMT 350/304/456 And
Standard Constant Current
Welding Power Source
10-95 V
5-450 A
400 A @ 34 VDC,
100% Duty Cycle
Length: 420 mm
Width: 250 mm
Height: 265mm
13 Kg
3-3.
Environmental Specifications
A. IP Rating
IP Rating
Operating Temperature Range
IP23
This equipment is designed for outdoor use. It
may be stored, but is not intended to be used
outside during precipitation unless sheltered.
−10
°
C to 40
°
c (14
°
F to 104
°
F)
B. Information On Electromagnetic Fields (EMF)
!
This equipment shall not be used by the general public as the EMF limits for the general public might be exceeded during welding.
This equipment is built in accordance with EN 60974−1 and is intended to be used only in an occupational environment (where the general public
access is prohibited or regulated in such a way as to be similar to occupational use) by an expert or an instructed person.
Wire feeders and ancillary equipment (such as torches, liquid cooling systems and arc striking and stabilizing devices) as part of the welding
circuit may not be a major contributor to the EMF. See the Owner’s Manuals for all components of the welding circuit for additional EMF exposure
information.
S
The EMF assessment on this equipment was conducted at 0.5 meter.
S
At a distance of 1 meter the EMF exposure values were less than 20% of the permissible values.
ce-emf 1 2010-10
Notes