OM-275857 Page 17
�
Complete Parts List is available at www.MillerWelds.com
B. Welding Power Source With Cart And Cooler
A complete Parts List is available at www.MillerWelds.com
1-3.
Dimensions, Weights And Base Mounting Hole Layout
A. Welding Power Source
B
A
C
803914-A
C
D
F
G
E
B. Welding Power Source With Cart And Cooler
B
A
C
804642-C
Dimensions
A
400 Amp Models
43-1/8 in. (1095 mm)
800 Amp Models
53-3/4 in. (1365 mm)
B
23-1/8 in. (587 mm)
C
43-3/4 in. (1111 mm)
Weight
400 Amp Models
250.5 lb (113.6 kg)
800 Amp Models
313 lb (142 kg)
4-6.
Environmental Specifications
A. IP Rating
IP Rating
IP23
This equipment is designed for outdoor use.
B. Temperature Specifications
Operating Temperature Range
*
Storage/Transportation Temperature Range
14 to 104°F (-10 to 40°C)
-4 to 131°F (-20 to 55°C)
*Output is derated at temperatures above 104°F (40°C).
C. Information On Electromagnetic Compatibility (EMC) (Dynasty 400)
This Class A equipment is not intended for use in residential locations where the electrical power is provided by the public
low-voltage supply system. There can be potential difficulties in ensuring electromagnetic compatibility in those locations,
due to conducted as well as radiated disturbances.
This equipment complies with IEC61000-3-11 and IEC 61000-3-12 and can be connected to public low-voltage systems provided that the pub-
lic low-voltage system impedance Z
max
at the point of common coupling is less than 47.2 mΩ (or the short-circuit power S
sc
is greater than
3,746,329 VA). It is the responsibility of the installer or user of the equipment to ensure, by consultation with the distribution network operator
if necessary, that the system impedance complies with the impedance restrictions.
D. Information On Electromagnetic Compatibility (EMC) (Maxstar 400)
This Class A equipment is not intended for use in residential locations where the electrical power is provided by the public
low-voltage supply system. There can be potential difficulties in ensuring electromagnetic compatibility in those locations,
due to conducted as well as radiated disturbances.
This equipment complies with IEC61000-3-11 and IEC 61000-3-12 and can be connected to public low-voltage systems provided that the pub-
lic low-voltage system impedance Z
max
at the point of common coupling is less than 47.2 mΩ (or the short-circuit power S
sc
is greater than
3,746,329 VA). It is the responsibility of the installer or user of the equipment to ensure, by consultation with the distribution network operator
if necessary, that the system impedance complies with the impedance restrictions.
Содержание Dynasty 400
Страница 77: ...OM 275857 Page 67 SECTION 12 ELECTRICAL DIAGRAMS 275852 H Figure 12 1 Dynasty 400 Circuit Diagram Page 1 of 2...
Страница 78: ...OM 275857 Page 68 275852 H Figure 12 2 Dynasty 400 Circuit Diagram Page 2 of 2...
Страница 80: ...OM 275857 Page 70 Figure 12 4 Maxstar 400 Circuit Diagram Page 2 of 2...
Страница 81: ...OM 275857 Page 71 275854 G Figure 12 5 Dynasty 800 Circuit Diagram Page 1 of 2...
Страница 82: ...OM 275857 Page 72 275854 G Figure 12 6 Dynasty 800 Circuit Diagram Page 2 of 2...
Страница 83: ...OM 275857 Page 73 Figure 12 7 Maxstar 800 Circuit Diagram Page 1 of 2...