5-4. Troubleshooting Table
Trouble
Remedy
No weld output; unit completely
inoperative.
Place line disconnect switch in On position (see Section 3-15).
Check fuse F1, and replace if necessary (see Section 5-2).
Check and replace line fuse(s), if necessary, or reset circuit breaker (see Section 3-15).
Check for proper input power connections (see Section 3-15).
Check for proper jumper link position (see Section 3-15).
No weld output; Power switch pilot light
on; fan on.
Check, repair, or replace feeder (see wire feeder Owner’s Manual).
Unit overheated. Allow unit to cool with fan On (see Section 3-3).
Have Factory Authorized Service Agent check control board PC1.
Unit provides only maximum or mini-
mum weld output.
Have Factory Authorized Service Agent check control board PC1.
Erratic or improper weld output.
Use proper size and type of weld cable (see Section 3-9).
Clean and tighten all weld connections.
Check wire feeder installation according to Owner’s Manual.
Have Factory Authorized Service Agent check control board PC1 and/or SCR in main rectifier.
No 115 volts AC output at duplex
receptacle or Remote 14 receptacle.
Reset supplementary protector CB1 (see Section 3-8).
No 24 volts AC output at Remote 14
receptacle.
Reset supplementary protector CB2 (see Section 3-8).
Fan not operating.
Check for and remove anything blocking fan movement.
Have Factory Authorized Service Agent check fan motor.