OM-2241 Page 17
3-12. Remote 14 Receptacle RC8 Information
Socket
Information
24 VOLTS AC
A
24 volts AC. Protected by supplementary protector CB2.
B
Contact closure to A completes 24 volts AC contactor control circuit.
REMOTE OUTPUT CONTROL
C
Command reference; 0 to +10 volts DC.
D
Remote control circuit common.
E
0 to +10 volts DC input command signal from remote control.
F
Current feedback; 1 volt per 100 amperes.
H
Voltage feedback; 1 volt per 10 arc volts.
115 VOLTS AC
I
115 volts, 15 amperes, 60 Hz AC. Protected by supplementary protector CB1.
J
Contact closure to I completes 115 volts AC contactor control circuit.
GND
K
G
Chassis common.
Circuit common for 24 and 115 volts AC circuits.
REMOTE POWER ON/OFF
To remote On/Off switch.
*
REMOTE VOLTAGE SENSING
*
Voltage sensing signal from Negative (
−
) weld output terminal.
*
Voltage sensing signal from Positive (+) weld output terminal.
* Not Used