10-1. Troubleshooting
Also see Voltmeter/Ammeter help displays to assist in troubleshooting weld problems (see Section 8-11). Also see Engine Information Display
to assist in troubleshooting engine related problems (see Section 13).
A. Welding
Trouble
Remedy
No weld output; generator power output
okay at AC receptacles.
Place Process/Contactor switch in an Electrode Hot position, or place switch in a Remote On/Off Re-
quired position and connect remote contactor to Remote receptacle (see Sections 5-17).
Reset supplementary protector CB3 (see Section 8-10).
Reset supplementary protector CB9 and/or CB29 (see Section 8-10). Check for faulty remote device
connected to Remote receptacle.
Check and secure connections to Remote receptacle (see Section 5-17).
Check fuse F2, and replace if open (see Section 8-10). Have Factory Authorized Service Agent check
brushes and slip rings, weld excitation circuit, and the rotor.
No weld output or generator power
output at AC receptacles.
Disconnect equipment from generator power receptacles during start-up.
Reset supplementary protector CB4 (see Section 8-10).
Check fuses F1 and F2, and replace if open (see Section 8-10). Have Factory Authorized Service Agent
check integrated rectifier SR2, capacitor C6, and the rotor.
Have Factory Authorized Service Agent check brushes and slip rings, and field excitation circuit.
Erratic weld output.
Check and tighten connections inside and outside unit.
Be sure connection to work piece is clean and tight.
Use dry, properly stored electrodes.
Remove excessive coils from weld cables.
Have Factory Authorized Service Agent check brushes and slip rings.
High weld output.
Check position of Voltage/Amperage Adjust control.
Have engine Factory Authorized Service Agent check engine speed.
Have Factory Authorized Service Agent check voltage feedback circuit.
Low weld output.
Check position of Voltage/Amperage Adjust control.
Have engine Factory Authorized Service Agent check engine speed.
Check fuses F1 and F2, and replace if open (see Section 8-10). Have Factory Authorized Service Agent
check integrated rectifier SR2, capacitor C6, and the rotor.
Low open-circuit voltage.
Have engine Factory Authorized Service Agent check engine speed.
Check position of Process/Contactor switch.
No remote fine amperage or voltage
control.
Check and secure connections to Remote receptacle (see Section 5-17).
Repair or replace remote control device.
Have Factory Authorized Service Agent check current sensing devices, and connections.
Constant speed wire feeder does not
work.
Reset supplementary protector CB9 or CB29 (see Section 8-10).
Check and secure connections to Remote receptacle (see Section 5-17).
Repair or replace wire feeder.
Содержание Big Blue 800 X Duo Air Pak
Страница 53: ... Complete Parts List available at www MillerWelds com OM 282374 Page 49 6 13 Fuel Hour Gauge Descriptions ...
Страница 77: ... Complete Parts List available at www MillerWelds com OM 282374 Page 73 Notes ...
Страница 78: ...OM 282374 Page 74 SECTION 12 ELECTRICAL DIAGRAMS Figure 12 1 Circuit Diagram For Welder Generator ...
Страница 79: ...OM 282374 Page 75 281933 C ...