8-11. Voltmeter/Ammeter Error Displays
Display Example
Use the Voltmeter/Ammeter error displays to diagnose and correct fault conditions.
When an error is displayed, normally weld output has stopped but generator power output may be okay.
To reset error displays, stop unit and then restart. See below to reset CHEK REMT display.
IGBT
TEMP
Error Display
Description
CHEK REMT
Indicates a remote device connected to the Remote Receptacle may be faulty. CHEK REMT is also displayed whenever a
remote device has been connected to the Remote Receptacle and then disconnected. Clear fault by stopping and restarting
the unit, or by pressing and releasing the Adjust Control/Select button. If problem continues, have Factory Authorized Service
agent check the remote device and main control board PC1/PC21.
IGBT 1SHT
Indicates the thermistor in IGBT module 1 has shorted. Have Factory Authorized Service Agent check unit.
IGBT 1OPN
Indicates the thermistor in IGBT module 1 is open. Have Factory Authorized Service Agent check unit.
IGBT 2SHT
Indicates the thermistor in IGBT module 2 has shorted. Have Factory Authorized Service Agent check unit.
IGBT 2OPN
Indicates the thermistor in IGBT module 2 is open. Have Factory Authorized Service Agent check unit.
IGBT TEMP
Indicates an IGBT module has overheated. If this display is shown, check generator cooling system and/or reduce duty cycle.
Keep engine access door closed when running unit to maintain proper cooling airflow past module. Allow unit to cool before
restarting. If problem continues, have Factory Authorized Service Agent check unit.
MAX POWR
Engine power limit exceeded, causing weld output to be temporarily reduced. Error clears after 5 seconds.
S/W ERR
Software version mismatch occurred. Reload software update. If error does not clear, have Factory Authorized Service
Agent check unit.
S/W BLD
Software build mismatch occurred. Reload software update. If error does not clear, have Factory Authorized Service Agent
check unit.
COMM LOSS
Indicates a communication loss between control boards. Parallel mode will not function. Error can be cleared by pressing
and releasing the Adjust Control/Select button. Unit can operate in dual operator mode only after clearing error. If error
does not clear, have Factory Authorized Service Agent check unit.
Содержание Big Blue 800 X Duo Air Pak
Страница 53: ... Complete Parts List available at www MillerWelds com OM 282374 Page 49 6 13 Fuel Hour Gauge Descriptions ...
Страница 77: ... Complete Parts List available at www MillerWelds com OM 282374 Page 73 Notes ...
Страница 78: ...OM 282374 Page 74 SECTION 12 ELECTRICAL DIAGRAMS Figure 12 1 Circuit Diagram For Welder Generator ...
Страница 79: ...OM 282374 Page 75 281933 C ...