Complete Parts List available at www.MillerWelds.com
OM-282374 Page 36
5-17. Connecting To Remote 14 Receptacle
Rmt14_1 2010
−
04
OR
Accessories depend
on unit capabilities.
*The remaining sockets
are not used.
Socket*
Socket Information
Not all models have contactor control. See description of front panel controls and
circuit diagram.
24 VOLTS AC
A
24 volts AC. Protected by supplementary protector.
B
Contact closure to A completes 24 volt AC contactor
control circuit.
REMOTE
OUTPUT
CONTROL
C
Output to remote c10 volts DC in MIG mode;
0 to +10 volts DC in Stick or TIG mode.
D
Remote control circuit common.
E
DC input command signal: 0 to +10 volts from min.
to max. of remote control with Voltage/Amperage
Adjust control at maximum.
F
Current feedback: 1 volt per 100 amperes.
H
Voltage feedback: 1 volt per 10 arc volts.
GND
K
Chassis common.
NEUTRAL
G
Circuit common for 24 volt AC circuit.