OM-222 394 Page 21
6-7. Lower Display
1
Lower Display
The lower display shows WFS (wire feed
speed), AMPS (amperage), ARC CTL (arc
control), or Time. The feeder displays only
preset wire speed at idle (not welding). While
welding, the average amperage is displayed.
The lower display shows welding sequence
time when the Time LED is illuminated.
2
WFS (Wire Feed Speed) LED
LED illuminates to indicate the preset wire feed
value is being displayed and can be adjusted
using the Adjust knob.
3
Amps LED
LED illuminates to indicate the average
amperage is being displayed while welding
and for 3 seconds after welding is terminated.
The amperage must be above a minimum
value of 25 amps for this function to operate.
4
Arc Ctl (Arc Control) LED
LED illuminates to indicate that inductance
(MIG) or ARC [Pulse, Accu-pulse, or RMD
(optional)] is being displayed and can be ad-
justed using the Adjust knob.
5
Time LED
LED illuminates to indicate that a time value is
being displayed for a sequence function and
can be adjusted using the Adjust knob.
6
Lower Display Push Button
7
Lower Display Push Button LED
Pressing the button illuminates the LED and
selects either WFS or Arc Ctl value for
changing using the Adjust knob.
To select Arc Ctl, press and hold lower display
button for 2 seconds. The top display will show
either INDU for a MIG program or ARC for
Pulse, Accu-pulse, or RMD (optional). To exit
Arc Ctl or INDU, either press the upper display
push button or press and hold the lower display
push button for 2 seconds.
When the lower display push-button LED and
the WFS LED are both illuminated, it is
possible to change WFS while welding by
using the Adjust knob. The value in the display
will switch momentarily to show preset wire
feed speed while turning the Adjust knob and
revert back to actual value when adjustment is
completed.
When the Arc Ctl LED is illuminated, it is pos-
sible to change values while welding by using
the Adjust knob. To return to actual values on
the display, exit the Arc Ctl display.
.
The lower display push button has addi-
tional functions when entering the se-
quence and trigger control functions (see
Section 6-8).
6
1
3
2
7
WFS
Amps
Arc Ctl
4
Time
5
Содержание 394F
Страница 4: ......
Страница 34: ...OM 222 394 Page 30 SECTION 9 ELECTRICAL DIAGRAM Figure 9 1 Circuit Diagram...
Страница 35: ...OM 222 394 Page 31 218 564 D...