6.0
Definition of Controls
Delay Settings:
These are used to eliminate voids in seam. Remember to
test various drive delay settings to ensure quality welds. If the drive delay
is too long the material may be burnt.
Drive Start Delay Time:
Once the nozzle swings into position, the Drive
Start Delay Time will delay the weld rollers from turning until the set point
is reached. The Drive Start Delay Time will be adjusted by the operator to
the desired setting.
Language:
Select the language according to demand.
MAX Output:
1350˚F 32ft/min 50-100% blower.
Hour Meter
: The hour meter will count total time of which the heating
system is on.
Presets
: When changing parameters, pressing the SAVE button will save
the adjusted settings to the selected recipe.
Drive Delay
Language
Presets
Hour Meter