OM-4401 Page 14
3-8.
DC/CV MIG Volt-Ampere Curves
203 112
Volt-ampere curves show minimum
and maximum voltage and amper-
age output capabilities of unit.
Curves of other settings fall be-
tween curves shown.
0
5
10
15
20
25
30
35
40
45
0
100
200
300
400
500
600
DC AMPERES
DC VOL
TS
SECTION 4 – INSTALLATION
install1 10/00 – Ref. ST-800 652 / Ref. ST-800 477-A / ST-158 936-A / S-0854
Do not weld on base. Weld-
ing on base can cause fuel
tank fire or explosion. Bolt
unit down using holes pro-
vided in base.
Always securely fasten
welding generator onto
transport vehicle or trailer
and comply with all DOT and
other applicable codes.
Always ground generator
frame to vehicle frame to pre-
vent electric shock and static
electricity hazards.
1
Generator Base
2
Metal Vehicle Frame
3
Equipment Grounding
Terminal
4
Grounding Cable
Use #10 AWG or larger insulated
copper wire.
If unit does not have GFCI re-
ceptacles, use GFCI-
protected extension cord.
1
2
Electrically bond genera-
tor frame to vehicle frame
by metal-to-metal contact.
GND/PE
3
4
2
OR
OR
18 in
(460 mm)
18 in
(460 mm)
18 in
(460 mm)
18 in
(460 mm)
18 in
(460 mm)
OR
Movement
Airflow Clearance
Location
Grounding
Do not lift unit from end.
4-1.
Installing Welding Generator
Содержание Trailblazer Pro 350 D
Страница 4: ......
Страница 23: ...OM 4401 Page 19 Notes...
Страница 42: ...OM 4401 Page 38 SECTION 8 ELECTRICAL DIAGRAMS Figure 8 1 Circuit Diagram For Welding Generator...
Страница 43: ...OM 4401 Page 39 198 518 A...
Страница 64: ......
Страница 65: ......
Страница 66: ......