OM-4401 Page 11
6 Minutes Welding
4 Minutes Resting
3-4.
Duty Cycle And Overheating
Duty Cycle is percentage of 10 min-
utes that unit can weld at rated load
without overheating.
Exceeding duty cycle can
damage unit and void
warranty.
60% Duty Cycle at 350 Amperes DC
198 919
100
150
200
250
300
350
400
0
10
20
30
40
50
60
70
80
90
100
% DUTY CYCLE
WELD AMPERES
DC
AC
3-5.
AC Generator Power Curve
200 268
The ac power curve shows the gen-
erator power in amperes available
at the 120 and 240 volt receptacles.
0
50
100
150
200
250
300
0
10
20
30
40
50
60
70
80
90
AC AMPERES IN 240V MODE
0
25
50
75
100
150
125
0
20
40
80
100
140 160
AC AMPERES IN 120V MODE
60
120
180
AC VOL
TS
12 kW
Содержание Trailblazer Pro 350 D