OM-217 Page 27
Trouble
Remedy
Temperature Trouble light on; Ready
light off.
Thermostat TP1 and/or TP2 open (overheating). Allow fan to run; the thermostat closes when the unit has
cooled (see Section 3-2).
Have Factory Authorized Service Agent check timer/control board PC1.
No high gas/air flow (cutting air), or de-
creased cutting ability.
Check for sufficient gas/air supply pressure and correct gas/air pressure adjustment (see Section 4-1).
Have Factory Authorized Service Agent check reed switch RS1, high air solenoid AS2, and air circuitry.
Fan motor FM does not run; Power light
and Ready light both on.
Check fan motor connections.
Trouble lights not working.
Have Factory Authorized Service Agent check indicator board PC3 and timer/control board PC1.
Power light on; Trouble lights on; cutting
output available.
Have Factory Authorized Service Agent check timer/control board PC1.