OM-225 757 Page 18
4-3. Meter Functions For CC/CV Models
The meters display the actual weld output values for approximately three seconds
after the arc is broken.
NOTE
Mode
Meter Reading At Idle
Lift-Arc TIG
(GTAW)
V
A
Actual Volts
Preset Amps
8.0
85
TIG (GTAW)
Blank
Preset Amps
V
A
85
MIG (GMAW)
Preset Volts
Blank
V
A
24.5
Panel Control
SMAW
Actual Volts (OCV)
Preset Amps
V
A
80.0
85
4-4. Lift-Arc TIG Procedure For CC/CV Models
With Mode switch in the Lift-Arc TIG
position, start an arc as follows:
1
TIG Electrode
2
Workpiece
Touch tungsten electrode to work-
piece at weld start point,
hold
electrode to workpiece for 1-2
seconds
, and slowly lift electrode.
An arc will form when electrode is
lifted.
Normal open-circuit voltage is not
present before tungsten electrode
touches workpiece; only a low
sensing voltage is present between
electrode and workpiece. The
solid-state output contactor does
not energize until after electrode is
touching workpiece. This allows
electrode to touch workpiece with-
out overheating, sticking, or getting
contaminated.
1
1
−
2
Seconds
“Touch”
Do NOT Strike Like A Match!
2