OM-805 Page 9
5-2.
Overload Protection
READ SAFETY BLOCKS at start of
Section 5 before proceeding.
WARNING
Fuse link F1 protects the grid from
overload damage. If weld output
stops, check fuse link as follows:
Turn Off welding power source and
disconnect input power.
1
Fuse Link F1 (See Parts List
For Rating)
Check and replace fuse link, if
necessary.
Close rear access door.
1
Ref. ST-080 152-C
7/16 in
Tools Needed:
Figure 5-2. Fuse Link Location
5-3.
Troubleshooting
WARNING
ELECTRIC SHOCK can kill.
•
Do not touch live electrical parts.
•
Turn Off welding power source, and disconnect
input power before inspecting, maintaining, or
servicing.
HOT PARTS can cause severe burns.
•
Allow cooling period before servicing.
Troubleshooting to be performed only by qualified
persons.
swarn9.1 2/93
Table 5-1. Welding Trouble
Trouble
Remedy
Section
No weld output.
Check and replace open fuse link, if necessary.
5-2
Check electrical input and output connections.
3-3
Erratic or improper weld output.
Select correct size weld cables according to Table 3-1.
– –
Clean and tighten weld cable connections.
3-3