.
A complete Parts List is available at www.MillerWelds.com
OM-230 693 Page 32
Trouble
Remedy
No wire feed.
Turn Wire Speed control to higher setting (see Section 5-1).
Clear obstruction in gun contact tip or liner (see welding gun Owner’s Manual).
Readjust drive roll pressure (see Section 4-14).
Change to correct size drive rolls (see Section 6-3).
Rethread welding wire (see Section 4-14).
HL.P 002 appears on meters. Thermistor T is detecting an overheating condition. Wait for unit to cool
allowing the fan to run. After unit is cool, If HL.P 002 message remains, contact Factory Authorized
Service Agent (see Section 6-2).
HL.P 004 appears on meters. Reset message by releasing the trigger or removing stuck wire causing
short circuit (see Section 5-2) . If message remains, have Factory Authorized Service Agent check for
shorted trigger leads.
HL.P 005 appears on meters. Wire feed malfunction. Check wire feed delivery system.
Check gun trigger and leads. Repair or replace gun if necessary.
Have Factory Authorized Service Agent check main control board.
Содержание Millermatic 252
Страница 14: ...OM 230 693 Page 10...
Страница 25: ...A complete Parts List is available at www MillerWelds com OM 230 693 Page 21 Notes...
Страница 26: ...A complete Parts List is available at www MillerWelds com OM 230 693 Page 22 4 15 Weld Parameters...
Страница 27: ...A complete Parts List is available at www MillerWelds com OM 230 693 Page 23 226 650 B...
Страница 37: ...OM 230 693 Page 33 Notes...
Страница 38: ...OM 230 693 Page 34 SECTION 7 ELECTRICAL DIAGRAM Figure 7 1 Circuit Diagram...
Страница 39: ...OM 230 693 Page 35 229 485 A...