OM-1308 Page 12
SECTION 4 – MAINTENANCE AND TROUBLESHOOTING
4-1.
Routine Maintenance
Y
Disconnect power before maintaining.
3 Months
Replace unreadable labels.
Repair or replace
cracked weld cable.
Clean and tighten weld terminals.
6 Months
Blow out or vacuum inside. during
heavy service clean monthly.
OR
Remove drive roll and
carrier. Apply light coat
of oil or grease to drive
motor shaft.
4-2.
Circuit Breaker CB1
Ref. ST-148 261-C
1
Circuit Breaker CB1
If CB1 opens, wire feeding stops.
2
Welding Gun
Check gun liner for blockage or
kinks.
3
Wire Drive Assembly
Check for jammed wire, binding
drive gear or misaligned drive rolls.
Allow cooling period and reset
breaker. Close door.
1
2
3
4-3.
Unit Overload
If unit is used beyond capacity (excessive wire feed, shorted output, etc.), wire feeds but is not energized. Release gun
trigger to reset this condition.
Содержание Millermatic 250
Страница 4: ......
Страница 21: ...OM 1308 Page 17 SECTION 5 ELECTRICAL DIAGRAM SC 175 883 A Figure 5 1 Circuit Diagram...