5-9. Troubleshooting

Trouble

Remedy

No heat output.

Replace building line fuse or reset circuit breaker.
Secure head/coil connecting plate to power source connecting block (see Section 3-2).
Check and replace Power switch if necessary.
Connect power source to proper input voltage or check for low line voltage.

No heat output; fan motor continues to run.

Safety interlock switch open. Reinstall wrapper (see Section 5-4).
Thermostat(s) TP1, TP2, and/or TP3 open (overheating). Allow fan to run; the thermostat(s) will close

when the unit has cooled (see Section 5-2).

Low heat output.

Check tuning of induction heating output system.

Current Source Fault LED (red) on.

Turn power off and back on again to power source one time. If fault does not clear, contact authorized

Factory Service Agent.

Over Frequency Fault LED (red) on.

Check for shorted coil or blanket.

Under Frequency Fault LED (red) on.

Check for open circuit coil or blanket.

Current Fault LED (red) on.

Check for shorted turn(s) in coil or blanket.

Tank Voltage Fault LED (red) on.

Check for unloaded (empty) coil.
Check for arcing between turns.

Line Voltage Fault LED (red) on.

Check input line voltage.

Ground Fault LED (red) on.

Check for output path to ground.
Check for human path to ground.

Load Fault LED (red) on.

Check for loose coupling between coil or blanket and workpiece or pipe.

Over Temperature Fault LED (yellow) on.

Check door switch.
Check for fan operation.
Clean unit.

Current Source Limit LED (yellow) on.

Check coupling between coil and load.

Over Frequency Limit LED (yellow) on.

Check for correct tank capacitance.
Check for shorted turns.

Under Frequency Limit LED (yellow) on.

Check for correct tank capacitance.

Current Limit LED (yellow) on.

Check tank capacitance.

Tank Voltage LED (yellow) on.

Check tuning of system (see Section 5-10).

5-10. Tuning Chart

Y

Energizing contactor without at least 1 tuning capacitor in output circuit will damage power

source.

DO NOT operate power source without at least 1 tuning capacitor in output circuit.

Voltage*

Current (Amperage)*

Frequency (KHz)

Corrective Action

High

Low

Low

Lower inductance or decrease matching transformer turns ratio

High

Low

High

Add capacitance

High

Low

Mid-Range

Decrease matching transformer turns ratio and add capacitance

Low

High

Low

Lower capacitance

Low

High

High

Increase matching transformer turns ratio, or lower capacitance and

increase inductance

Low

High

Mid-Range

Increase matching transformer turns ratio and lower capacitance

*High voltage > 650 V rms; Low voltage < 450 V rms; Operating current range: 0 to 750 A rms
The power source is factory set for 4.5 mfd, but is capable of being set for 6 mfd. If a certain application requires the higher capacitance setting, remove

insulator from front capacitor and connect with supplied hardware.

Содержание Intellifire 250

Страница 1: ...Intellifire 250 Processes Description Induction Heating Power Source Induction Heating OM 184 227K 2006 05 Visit our website at www MillerWelds com File Induction Heating...

Страница 2: ...inue the tradition They re just as committed to providing equipment and service that meets the high standards of quality and value established in 1929 This Owner s Manual is designed to help you get t...

Страница 3: ...6 SECTION 3 INSTALLATION 7 3 1 Specifications 7 3 2 Connecting Head Coil to Power Source 7 3 3 Remote 14 Receptacle RC14 Information and Connections 8 3 4 Remote 14 Socket Information 8 3 5 Connectin...

Страница 4: ......

Страница 5: ...imum length of 18 inches 457 mm to provide isolation D Properly install and ground this equipment according to its Owner s Manual and national state and local codes D Always verify the supply ground c...

Страница 6: ...ed person familiar with electronic equipment per form this installation D The user is responsible for having a qualified electrician promptly correct any interference problem resulting from the instal...

Страница 7: ...systems While most of this work is of very high quality the results are complex Current scientif ic understanding does not yet allow us to interpret the evidence in a single coherent framework Even m...

Страница 8: ...orrectement la terre conform ment au manuel utilisateur et aux codes nationaux gouvernementauxet locaux 8 V rifier souvent la terre de l alimentation contr ler et s assurer que le conducteur de terre...

Страница 9: ...l unit s assurer que les fourches sont suffisamment longues pour d passer du c t oppos de l appareil LA PROJECTION DE PIECES DE METAL ou DE COLLE peut provoquer des blessures aux yeux 1 Porter des lu...

Страница 10: ...nclusions d finitives en ce qui concerne les probl mes de risque possible ou de proposer des recommandations scientifiques claires pour des strat gies suivre en vue de minimiser ou de pr venir des ris...

Страница 11: ...with radio navigation safety services computers and communications equipment Have only qualified person familiar with electronic equipment perform this installation The user is responsible for having...

Страница 12: ...Contact closure to A completes 24 volts dc contactor control circuit C Command reference 10 volts dc Remote Output Control D Control circuit common Remote Output Control E Input command signal potent...

Страница 13: ...d through strain re lief and tighten screws 3 Fuse Block Cover Remove fuse block cover 4 Machine Grounding Terminal 5 Green Or Green Yellow Grounding Conductor Connect green or green yellow grounding...

Страница 14: ...flexible cord and cable requirements SECTION 4 OPERATION Ref ST 801 826 C 4 1 Controls 1 2 3 4 1 Power Adjust Control Use control to select power between the mini mum and maximum output of the power s...

Страница 15: ...or TP3 opens and output stops The fan keeps running to cool the heat sink s Wait several minutes before trying to heat 5 3 Automatic Shutdown Protection This unit automatically shuts down upon sensing...

Страница 16: ...they have discharged before working on unit 3 8 in Turn Off power source and disconnect input power Remove wrapper 1 Tuning Capacitor C1 2 Tuning Capacitor C2 3 Tuning Capacitor C3 4 Voltmeter Check t...

Страница 17: ...using the conductor to come into contact with the workpiece or a heating coil touches the workpiece causing a short in the output circuit The supplied ground lead must be connectedbetween the workpiec...

Страница 18: ...y have discharged before working on unit Turn Off power source and disconnect input power Remove wrapper 1 Input Capacitor C2 2 Input Capacitor C1 3 Input Capacitor C4 4 Input Capacitor C3 5 Voltmeter...

Страница 19: ...d 9 Over Temp Lights when contactor is energized and over temperature condition is present Also indicates top cover is removed from unit 10 Tank Current Fault Value Preset At Factory 11 Ground Fault L...

Страница 20: ...upling between coil or blanket and workpiece or pipe Over Temperature Fault LED yellow on Check door switch Check for fan operation Clean unit Current Source Limit LED yellow on Check coupling between...

Страница 21: ...OM 184 227 Page 17 Notes...

Страница 22: ...OM 184 227 Page 18 SECTION 6 ELECTRICAL DIAGRAM Figure 6 1 Circuit Diagram...

Страница 23: ...OM 184 227 Page 19 204 963 A...

Страница 24: ...ON 7 PARTS LIST Hardware is common and not available unless listed Figure 7 1 Main Assembly 801 828 F 1 Fig 7 2 3 4 5 6 7 8 9 10 11 13 14 15 16 17 18 19 20 21 22 23 24 25 27 38 39 40 12 33 31 32 30 34...

Страница 25: ...PANEL front 1 23 S1 159 039 SWITCH rocker SPDT 15A 125VAC 1 24 NAMEPLATE order by model and serial number 1 25 S2 120 376 SWITCH rocker SPDT 4A 250VAC 1 26 135 299 LOCK shaft pot 1 27 171 007 KNOB 1 2...

Страница 26: ...USE mintr gl slo blo 2A 250V 2 6 098 376 HOLDER fuse mintr 1 7 CT1 184 840 TRANSFORMER current primary 1 PLG13 135 635 HOUSING PLUG PINS 1 155 748 BUS BAR lem 1 8 PC1 229 245 CIRCUIT CARD current sour...

Страница 27: ...PLUG SKTS 1 PLG28 131 054 HOUSING RCPT SKTS 1 PLG29 115 094 HOUSING PLUG SKTS 1 29 025 248 STAND OFF insul 250 20 x 1 250 4 30 179 875 BUS BAR diode RH 2 31 179 876 BUS BAR diode LH 2 32 C8 10 170 86...

Страница 28: ...Notes...

Страница 29: ...Notes...

Страница 30: ...Notes...

Страница 31: ...Heating Coils and Blankets Cables and Non Electronic Controls APT SAF Model Plasma Cutting Torches Remote Controls Accessory Kits Replacement Parts No labor Spoolmate Spoolguns Canvas Covers Miller s...

Страница 32: ...retain with your personal records Always provide Model Name and Serial Style Number Contact a DISTRIBUTOR or SERVICE AGENCY near you Welding Supplies and Consumables Options and Accessories Personal...

Отзывы: