OM-184 227 Page 7
SECTION 3
−
INSTALLATION
3-1. Specifications
Output
Frequency
Rated Output
Required
Reflective
Inductance
Amperes Input at
Rated Load Output 50
or 60 Hz, Three-Phase
Overall Dimensions
Weight
Frequency
Inductance
460 V
KVA
KW
10 To 50 kHz
25 kW At
100% Duty
Cycle
−
Max
750 A (RMS),
700 V (RMS)
2.5 To 50
μ
h
39
0.29*
30.8
27.19
Length: 31 in
(787 mm)
Width: 16 in
(406 mm)
Height: 27 in
(686 mm)
165 lb
(75 kg)
*While idling
WARNING
HIGH-FREQUENCY RADIATION can interfere with radio navigation, safety services,
computers, and communications equipment.
•
Have only qualified person familiar with electronic equipment perform this installation.
•
The user is responsible for having a qualified electrician promptly correct any interference problem resulting from the installation.
•
If notified by the FCC about interference, stop using the equipment at once.
•
Have the installation regularly checked and maintained.
•
Keep high-frequency source doors and panels tightly shut.
Ref. ST-801 826-C
Tools Needed:
3-2. Connecting Head/Coil to Power Source
1
Rear Panel
2
Connecting Block
.
Do Not Exceed 58 in lb
(6.6 N
.
m) of torque when
making connections.
7/16 in
2
1
Содержание Intellifire 250