A complete Parts List is available at www.MillerWelds.com
OM-278 Page 18
4-13. TIG (GTAW) Cable Connections
+
+
−
Gas Flowmeter/
Regulator
HIGH
INDUCTANCE
Optional HF Unit
!
Turn Off power before making connections.
.
For better performance for most GTAW applications, it is
recommended that electrode negative (DCEN) weld output
connections be made to the high Inductance weld output ter-
minal. Make connections as shown.
4-14. Remote 14 Receptacle RC8 Information
Socket
Information
24 VOLTS AC
A
24 volts ac. Protected by supplementary protector CB2.
24 VOLTS AC
B
Contact closure to A completes 24 volts ac contactor control circuit.
C
Command reference; 0 to +10 volts dc (CC), +10 volts dc (CV).
REMOTE OUTPUT CONTROL
D
Remote control circuit common.
E
0 to +10 volts dc input command signal from remote control.
F
Current feedback; 1 volt per 100 amperes.
H
Voltage feedback; 1 volt per 10 arc volts.
115 VOLTS AC
I
115 volts, 15 amperes, 60 Hz ac. Protected by supplementary protector CB1.
115 VOLTS AC
J
Contact closure to I completes 115 volts ac contactor control circuit.
GND
K
G
Chassis common.
Circuit common for 24 and 115 volts ac circuits.
REMOTE POWER ON/OFF
*
To remote On/Off switch
REMOTE POWER ON/OFF
*
To remote On/Off switch.
REMOTE VOLTAGE SENSING
*
Voltage sensing signal from Negative (
−
) weld output terminal.
REMOTE VOLTAGE SENSING
*
Voltage sensing signal from Positive (+) weld output terminal.
* Not Used
Содержание Dimension 652
Страница 14: ...OM 278 Page 6...
Страница 34: ...OM 278 Page 26 SECTION 7 ELECTRICAL DIAGRAM Figure 7 1 Circuit Diagram...
Страница 35: ...OM 278 Page 27 218 514 B...
Страница 37: ......
Страница 38: ......