OM-491 Page 27
7-3. Servicing Air Cleaner
Ref. 187 602-A / 801 964 / Ref. 191 631-A
Stop engine.
Do not run engine without air
cleaner or with dirty element.
1
Evacuator Valve
2
Dust Cap
3
Element
4
Housing
Clean or replace element if dirty or
damaged. Replace element yearly
or after six cleanings.
To Clean air filter:
Wipe off cap and housing. Remove
cap and dump out dust. Wipe dust
from inside cap and housing with
damp cloth. Remove element and
reinstall cap.
Do not clean housing with air
hose.
Clean element with compressed
air. Max. air pressure: 100 psi (690
kPa). Replace element if it has
holes or damaged gaskets.
Reinstall element and cap
4
3
Blow
Inspect
2
1
7-4. Inspecting And Cleaning Optional Spark Arrestor Muffler
802 170-A / Ref. 191 631-A
Stop engine and let cool.
1
Spark Arrestor Muffler
2
Cleanout Plug
Remove plug and remove any dirt
covering cleanout hole.
3
Exhaust Pipe
Start engine and run at idle speed to
blow out cleanout hole. If nothing
blows out of hole, briefly cover end
of exhaust pipe with fireproof
material.
Stop engine and let cool.
Reinstall cleanout plug.
Tools Needed:
3
2
1
3/8 in
Содержание Big Blue 502P
Страница 4: ......
Страница 30: ...OM 491 Page 26 7 2 Maintenance Label...
Страница 39: ...OM 491 Page 35 Notes...
Страница 40: ...OM 491 Page 36 SECTION 8 ELECTRICAL DIAGRAMS Figure 8 1 Circuit Diagram For Welding Generator...
Страница 41: ...OM 491 Page 37 191 550 C...