OM-495 Page 80
Return To Table Of Contents
SECTION 13
−
RUN-IN PROCEDURE
13-1. Wetstacking
Do not perform run-in
procedure at less than 20
volts weld output and do not
exceed duty cycle or equip-
ment damage may occur.
1
Welding Generator
Run diesel engines near rated volt-
age and current during run-in period
to properly seat piston rings and
prevent wetstacking. See name-
plate, rating label, or specifications
section in this manual to find rated
voltage and current.
Do not idle engine longer than
necessary. Piston rings seat
faster if engine runs at weld/
power rpm, and the welding
generator is kept loaded during
run-in.
2
Engine Exhaust Pipe
Wetstacking is unburned fuel and
oil in the exhaust pipe and occurs
during run-in if the engine is run too
long at light load or idle rpm.
If exhaust pipe is coated with a wet,
black, tar-like substance, dry the
engine using one of the following
run-in procedures.
See the engine manual for addition-
al engine run-in information.
2
1
Содержание Big Blue 402D
Страница 39: ...OM 495 Page 33 Return To Table Of Contents Notes...
Страница 43: ...OM 495 Page 37 Return To Table Of Contents Notes...
Страница 54: ...OM 495 Page 48 Return To Table Of Contents 9 2 Maintenance Label...
Страница 62: ...OM 495 Page 56 Return To Table Of Contents 10 2 Maintenance Label...
Страница 75: ...OM 495 Page 69 Return To Table Of Contents 215 302 A...
Страница 77: ...OM 495 Page 71 Return To Table Of Contents 216 530 A...
Страница 79: ...OM 495 Page 73 Return To Table Of Contents 215 303 A...
Страница 81: ...OM 495 Page 75 Return To Table Of Contents 216 531 A...
Страница 83: ...OM 495 Page 77 Return To Table Of Contents 215 298 A...
Страница 85: ...OM 495 Page 79 Return To Table Of Contents 215 299 A...
Страница 114: ......