OM-496 Page 50
Return To Table Of Contents
9-9.
Diagnosing Causes Of Engine Fault Shutdowns
Ref. 201 841
Use the front panel engine lights to
help determine the cause of an au-
tomatic engine shutdown.
Correct the cause of the shut-
down before operating the
welding generator.
This unit does not have a bat-
tery charging fault shutdown.
The engine continues to run if
the Battery Charging Light
goes on.
Normal Condition:
Oil Pressure Light On;
Battery Charging And Temperature Lights Off.
If Oil Pressure Light Is Off, See Factory Authorized Service Agent.
If Battery Charging Light Is On, Have Factory Authorized Service Agent
Check Alternator.
If Temperature Light Is On, Correct Cause Of Overheating
(See Engine Manual).
If Engine Is Okay, See Factory Authorized Service Agent.
Start Engine (With No Load Applied).
Continue Pressing Shutdown Switch
Until Engine Lights Go Off.
Normal Condition:
Engine Lights Go Off As Engine Reaches
Normal Operating Condition.
Lights That Stay On After 20 Sec. Indicate Fault
Condition.
Stop Engine And Correct Fault (See Above) If Fault
Continues, See Factory Authorized Service Agent.
Turn Engine Control Switch To Run/Idle
Position While Pressing Magnetic
Shutdown Switch.
20s
Pre-Start Diagnostic Checks
Diagnostic Checks While Running
Содержание Big Blue 302P
Страница 39: ...OM 496 Page 33 Return To Table Of Contents Notes...
Страница 61: ...OM 496 Page 55 Return To Table Of Contents Notes...
Страница 63: ...OM 496 Page 57 Return To Table Of Contents 215 296 B...
Страница 64: ...OM 496 Page 58 Return To Table Of Contents Figure 10 2 Circuit Diagram For CC CV Welding Generator...
Страница 65: ...OM 496 Page 59 Return To Table Of Contents 215 297 B...
Страница 93: ......
Страница 94: ......