OM-496 Page 32
Return To Table Of Contents
6-3.
Remote Amperage Control On CC Models (Optional)
1
Remote Amperage Adjust
Receptacle RC13
Connect optional remote control to
RC13 (see Section 5-10).
Example: Combination Remote Amperage Control (Stick)
Adjust Optional Remote Control
Set Switches
Set Range
Set Control
Ref. 154 862-A / Ref. 181 711-A / 802 311
In Example:
Range = 100 to 205 A DC
Percentage Of Range = 50%
Max = About 153 A DC (50% of 100 to 205)
Max (153 A DC)
Min (75 A DC)
1
6-4.
Weld Control/Arc Condition Information Label
Set weld controls as shown to
achieve softer or stiffer arc condi-
tions for different applications.
212 944-A
Содержание Big Blue 302P