OM-477 Page 22
6-2.
240 Volt Duplex Receptacle (Optional)
Ref. ST-181 711-A / Ref. ST-174 408
If unit does not have GFCI re-
ceptacles, use GFCI-pro-
tected extension cord.
1
240 V 15 A AC Receptacle
RC1
Receptacle supplies 60 Hz single-
phase power at weld/power speed.
Maximum output is 3 kVA/kW.
2
Circuit Breaker CB1
3
Circuit Breaker CB2
CB1 and CB2 protect the recep-
tacles from overload. If CB1 or CB2
opens, the 240 V receptacle and
half of the 120 V receptacle does
not work. 120 volts may still be
present at the 240 V receptacle.
Press button to reset circuit
breaker.
If a circuit breaker continues to
open, contact a Factory
Authorized Service Agent.
Combined output of all receptacles
is 3 kVA/kW. Auxiliary power is not
affected by weld output.
EXAMPLE: If 10 A is drawn from the
240 V receptacle, only 5 A is avail-
able at the 120 V receptacle:
(240 V x 10 A) + (120 V x 5 A) = 3.0
kVA/kW