OM-203 034 Page 22
5-3. Meter Functions For CV Only Models
.
The meters display the actual weld output values for approximately three seconds after the arc is broken.
Mode
Meter Reading At Idle
Meter Reading While Welding
MIG
Preset Volts
Blank
V
A
24.5
Actual Volts
Actual Amps
V
A
24.5
250
Pulsed
MIG
Pulse Display
Pulse Display
V
A
PPP
PPP
Actual Volts
Actual Amps
V
A
24.5
250
5-4. Front Panel Controls For CC/CV Models
1
Power Switch
.
The fan motor is thermostatically
controlled and only runs when cooling is
needed.
2
Voltmeter (see Section 5-5)
3
Ammeter (see Section 5-5)
4
V/A (Voltage/Amperage) Adjust Control
5
Voltage/Amperage Control Switch
For front panel control, place switch in Panel
position and use the V/A Adjust control.
For remote control, make connections to Re-
mote 14 receptacle, and place switch in Re-
mote position. In most modes, remote control
is a percent of the V/A Adjust control setting.
Value selected on V/A Adjust is maximum
available on remote. In the MIG mode, re-
mote control provides full range of unit output
regardless of V/A Adjust control setting.
6
Mode Switch
The Mode switch setting determines both the
process and output On/Off control (see Sec-
tion 5-6). Source of control (panel or remote)
for the amount of output is selected on the V/A
Control switch.
For Air Carbon Arc (CAC-A) cutting and
gouging, place switch in the Stick position.
For best results, place Inductance/Dig con-
trol in the maximum position.
7
Inductance/Dig Control
Control adjusts Dig when the Stick or CC
mode is selected on the Mode switch. When
set towards minimum, short-circuit amper-
age at low arc voltage is the same as normal
welding amperage.
When set towards maximum, short-circuit
amperage is increased at low arc voltage to
assist with arc starts as well as reduce stick-
ing while welding (see volt-ampere curves in
Section 4-3).
Select setting best suited for application.
Control adjusts inductance when MIG posi-
tion is selected on the Mode switch. Induc-
tance determines the “wetness” of the weld
puddle. When set towards maximum, “wet-
ness” (puddle fluidity) increases.
When Pulsed MIG, or one of the TIG modes
is selected, this control is not functional.
2
3
4
7
196 445
1
5
6
Содержание 456 CC
Страница 4: ......
Страница 14: ...OM 203 034 Page 10...
Страница 34: ...OM 203 034 Page 30 SECTION 7 ELECTRICAL DIAGRAM Figure 7 1 Circuit Diagram For CV Only Welding Power Source...
Страница 35: ...OM 203 034 Page 31 239 524 A...
Страница 36: ...OM 203 034 Page 32 Figure 7 2 Circuit Diagram For CC CV Welding Power Source...
Страница 37: ...OM 203 034 Page 33 239 526 A...
Страница 41: ...Notes 229895 MATERIAL THICKNESS GAUGE...
Страница 42: ...Notes Work like a Pro Pros weld and cut safely Read the safety rules at the beginning of this manual...