User settings on the Low Compensation (LFL/LFR) and high compensation (HFL/HFR) boards
The clockwise most (full CW) setting on the Low
and High Compensation network settings
(marked “700 USER” and “-16.0 USER” can be
changed to a custom response by plugging in
different value capacitors into the filter boards
that are connected to the respective selection
knob on the front panel. To change the value,
unplug the unit from power, remove the top
panel (12 screws) and carefully remove the
capacitors from location C12/C14 and replace
with selected value from table. Either socket
may be used, Note that only the two OUTSIDE
pins of each connector are connected. See
pictures for placement.
Top view low comp
C12/C14 value (s)
+3dB point
4.3 uF
1KHz
3.3 uF
1.3KHz
2.5 uF
1.8KHz
2.0 uF
2.15KHz
1.0 uF
3.9KHz
Stock value- 5.17 uF (4.7uF +0.47uF)