background image

4K HDBaseT 4x4 Matrix Switcher

 

 

15 

4.3 RS232 Control 

4.3.1 Connection with RS232 Communication Port 

Except the front control panel, the MPM-44-IR-N can be controlled by far-end control 
system through the RS232 communication port. This RS232 communication port is a 
female 9-pin D connector. The definition of its pins is listed in the table below. 

 

No. 

Pin 

Function 

N/u 

Unused 

Tx 

Transmit 

Rx 

Receive 

N/u 

Unused 

Gnd 

Ground 

N/u 

Unused 

N/u 

Unused 

N/u 

Unused 

N/u 

Unused 

 

4.3.2 Control through 9-pin RS232 port 

Connect a control device to the 9-pin RS232 port of the switcher; users are able to 
control the switcher& far-end device. See the figure below: 

 

Control the switcher& 3rd-party Device through 9 pin female RS232 port 

  Control the switcher: send RS232 commands directly

 

  Control 3

rd

 party: send command: 

/+[Y]/[X]:******.

” (Refer to        for detailed 

information.)

 

4.3.3 Control through 3-pin RS232 port 

 

Control 3rd party device from local 

Connect the RS232 (3-pin pluggable terminal block) port in any zone to PC, and 

PC

PoC

3rd party

MPTP-T70R

Содержание MPM-44-IR-N

Страница 1: ...MPM 44 IR N 4K HDBaseT 4x4 Matrix Switcher All Rights Reserved Version MPM 44 IR N_2016V1 0 User Manual...

Страница 2: ...uipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications It has been teste...

Страница 3: ...or install this product near water Do not put any heavy items on the extension cable in case of extrusion Do not remove the housing of the device as opening or removing housing may expose you to dang...

Страница 4: ...Operations 8 4 1 Front Panel Button Control 8 4 1 1 Switching I O connection 8 4 1 2 EDID Management 8 4 1 3 Inquiry 10 4 1 4 Clear operation 11 4 2 IR Control 11 4 2 1 Usage of IR Remote 11 4 2 2 Fo...

Страница 5: ...her 4 4 TCP IP Control 23 4 4 1 Control Modes 24 4 4 2 GUI for TCP IP control 25 4 4 3 GUI Update 28 4 5 Firmware Update via USB 28 5 Specification 30 6 Panel Drawing 31 7 Troubleshooting Maintenance...

Страница 6: ...utput via HDMI outputs HDBaseT outputs and the audio output sockets The unit also supports bi directional RS232 IR control 1 2 Features Support HDMI 1 4 HDCP2 2 and compliant with lower standards capa...

Страница 7: ...ars 6 x Screws 1 x RS232 cable 1 x IR Receiver 4 x Plastic cushions 4 x Black Screws 1 x IR remote 1 x Power Adapter DC 24V 2 5A 8 x Pluggable Terminal Blocks 1 x User manual Notes Confirm if the prod...

Страница 8: ...ck lit buttons ranging from 1 to 4 Output 1 2 support synchronous local HDMI output EDID Invoking mode press and hold EDID button for 3 seconds or more to enter this mode in this mode button 1 2 are u...

Страница 9: ...d IR input for the output cannot be switched separately It makes up an IR bi directional transmission with the IR OUT on the corresponding HDBaseT receiver b COAX HDMI de embedded digital audio output...

Страница 10: ...t with extended IR receiver use the IR remote to control MPM 44 IR N TCP IP TCP IP port for unit control RS232 Serial port for unit control 9 pin female connector connects with control device such as...

Страница 11: ...rence system television education and bank securities institutions etc 3 2 Usage Precautions 1 System should be installed in a clean environment and has a prop temperature and humidity 2 All of the po...

Страница 12: ...via its built in IR sensor or through external IR receiver connected to the IR IN IR EYE IR ALL IN port The IR signal can be transmitted bi directionally between MPM 44 IR N and far end receivers 8 Co...

Страница 13: ...output the corresponding IR OUT will be switched synchronously 2 To convert an input to several outputs Operation input output output ENTER Example Switch input 2 to output 2 4 3 To convert an input t...

Страница 14: ...voking There are five types of embedded EDID data The chart below illustrates the detailed information of the embedded EDID data No EDID Data 1 1080P 2D 2CH 2 1080P 3D 2CH 3 1080P 2D Multichannel 4 10...

Страница 15: ...s next items Function Items Example Description Check the connection status of inputs Y means the corresponding port is connected with input device N means not Check the connection status of outputs Y...

Страница 16: ...on technology the MPM 44 IR N has some functions as follows 1 Control far end output device from local 2 Control local input output device remotely 3 Control the MPM 44 IR N locally remotely 4 2 1 Usa...

Страница 17: ...port of the matrix is not with IR carrier send the command 0901 to enter infrared carrier enforcing mode and then IR signal can be transferred to IR OUT port 4 2 3 Control Far end Device locally Conn...

Страница 18: ...with carrier 4 2 4 Control Local Device Remotely Connect IR receiver s to IR IN on far end HDBT receiver s and IR Emitter s to IR OUT port of the switcher and use the IR Remote of local souce to contr...

Страница 19: ...is transferred to IR OUT port and received by controlled device Switching Operation 4 IR IN ports correspond with 4 HDMI input ports separately in default mode a Sending command reference to 4 3 RS23...

Страница 20: ...5 Gnd Ground 6 N u Unused 7 N u Unused 8 N u Unused 9 N u Unused 4 3 2 Control through 9 pin RS232 port Connect a control device to the 9 pin RS232 port of the switcher users are able to control the...

Страница 21: ...ck port in any zone to controlled device 3rd party device and connect PC to the corresponding same zone as controlled device receiver see below Control 3rd party device from remote 4 3 4 Installation...

Страница 22: ...face of the control software is showed as below Please set the parameters of COM number baud rate data bit stop bit and the parity bit correctly only then will you be able to send command in Command S...

Страница 23: ...VX X X Demo Switch to the demo mode convert input and output in turn like1B1 1B2 4B3 4B4 1B1 and so on The switching interval is 2 seconds Demo Mode AV 01 01 IR 01 01 AV 01 02 IR 01 02 AV 04 04 IR 04...

Страница 24: ...e output channels one by one AV 01 01 AV 04 04 IR 01 01 IR 04 04 Save Y Save the present operation to the preset command Y ranges from 0 to 9 Save To FY Y 0 9 Recall Y Recall the preset command Y Reca...

Страница 25: ...given baud rate depended by the value of X a Y 1 4 send this command to the corresponding HDBaseT receiver to control far end device b Y 5 send this command to all HDBaseT receivers to control all fa...

Страница 26: ...racter EDIDMInit Restore the factory default EDID data of every input EDIDMInit EDIDM X B Y Manually EDID switching Enable input Y to learn the EDID data of output X If the EDID data is not available...

Страница 27: ...ment activate carrier native mode 0801 0900 Switch to carrier native mode Carrier native 0901 Switch to force carrier mode Force carrier 0911 Reset to factory default Factory Default 9951 Check the co...

Страница 28: ...N 9975 Check the I O connection status Out 01 02 03 04 In 04 04 04 04 9976 Check the output resolution Out 1 1920x1080 Out 2 1920x1080 Out 3 1920x1080 Out 4 1920x1080 9977 Check the status of digital...

Страница 29: ...IR N s Default 192 168 0 178 Controlled by PC s in LAN Connect MPM 44 IR N a router and several PCs to setup a LAN as shown in the following figure Set the network segment of MPM 44 IR N to the same...

Страница 30: ...e via GUI 4 4 2 GUI for TCP IP control MPM 44 IR N provides with built in GUI for convenient TCP IP control GUI allows users to interact with MPM 44 IR N through graphical icons and visual indicators...

Страница 31: ...ding button Buttons 1 9 at the right bottom corner provides quick saving and recall for overall connection status Users Display or modify credential settings front panel lock and GUI version If there...

Страница 32: ...trix Switcher 27 Configuration Set HDCP Cmpliance status for every input and manage EDID See the screenshot below Network Inquire and configure network settings including MAC address IP address subnet...

Страница 33: ...r that click Administration at the source menu to get to Upload Program as shown below Select the desired update file and press Apply it will start upgrading then 4 5 Firmware Update via USB HDBaseT 4...

Страница 34: ...It will enter the upgrade interface shown as below Step4 Click Connect USB Step5 Click Open to load the upgrade file then click Updata to start firmware upgrading Note To ensure available control the...

Страница 35: ...ax EDID Management In built EDID data and manual EDID management HDCP Supports HDCP 2 2 auto and manual HDCP management Audio General Output Signal Stereo audio Digital audio Output Connector 4 3 pin...

Страница 36: ...4 x 235 mm 1U high full rack wide Weight 2 0Kg 6 Panel Drawing INPUTS MENU 436 mm 23 mm 44 mm 32 mm RS232 IR EYE TCP IP HDMI INPUTS IR OUT 1 2 3 4 1 2 3 4 OUTPUTS HDMI AUDIO HDBaseT HDMI 2 3 4 L R AUD...

Страница 37: ...P compliance status in GUI The display doesn t support the input resolution Switch for another input source or enable the display to learn the EDID data of the input Cannot control the device via fron...

Страница 38: ...port Wrong connection Check to ensure the connection between the control device and the unit Wrong RS232 communication parameters Type in correct RS232 communication parameters Baud rate 9600 Data bi...

Страница 39: ...or removed from the product Damage deterioration or malfunction caused by Normal wear and tear Use of supplies or parts not meeting our specifications No certificate or invoice as the proof of warrant...

Отзывы: