Compact Scaler Switcher (with PoC)
14
4.3 Operations of CEC Function
MP-SC-5T supports CEC, it can be turned on/ off by sending RS232 commands or OSD
menu operations. The default setting is ON.
Commands pertaining to CEC:
“50686%” (enable CEC) and “50687%” (disable CEC)
HDMI INPUT ports 1~3 support CEC, if the connected source devices also support CEC
and their CEC are on, users can control the source device via the IR remote of
MP-SC-5T.
The working status related to CEC and STANDBY is showed as below:
Situation
Working Status
CEC: on, Standby: on
Press STANDBY button on IR remote, MP-SC-5T enters in
standby mode, so do all HDMI source devices.
Press STANDBY button again on IR remote, MP-SC-5T exits
standby mode, the HDMI source devices start working too.
CEC: on, Standby: off
Press STANDBY button on IR remote, MP-SC-5T enters in
standby mode, HDMI 1~3 source devices keep on.
CEC: on
Use CEC function buttons,
▲
,
▼
,
,
and
OK
buttons on
IR remote to control HDMI source devices, include play,
pause, fast forward, fast reverse and operations in menu.
CEC: off
Unable to control HDMI source devices through IR remote