Warranty

1. Extended Warranty Coverage

For a period of up to ten (10) years, Miles Industries Ltd., (the “Company”) or its appointed distributor will at its option pay the 
initial purchaser for the repair of, or will exchange the following parts or components which are found to be defective in material or 
workmanship under normal conditions of use and service:

2. Two-Year Parts Warranty 

In addition, for two (2) years from the date of purchase, the Company, at its option, can repair or exchange all parts and components 
not listed above but that are found to have a 

bona fi de

 defect in material or workmanship under normal conditions of use.

3. Conditions and Limitations

a)  The warranty registration card must be completed by the initial owner and returned to the Company within 90 days of purchase.
b)  Installation and maintenance must be performed by an authorized and trained dealer in accordance with the Company’s installation 

instructions.

c)  This warranty is void where installation of the unit does not conform to all applicable codes including national and local gas 

appliance installation codes and building and 

fi

 re codes.

d)  The owner must comply with all operating instructions.
e)  The Company is not responsible for the labor costs to remove defective parts or re-install repaired or replacement parts.
f) The 

fi

 rst purchaser or user of the unit will be responsible for any shipping charges for replacement parts as well as travel time 

incurred by the dealer to perform the warranty work.

g)  This warranty applies to non-commercial use and service and is void if it is apparent that there is abuse, misuse, alteration, 

improper installation, accident or lack of maintenance to the unit.

h)  This warranty does not cover damage to the unit through:

i) 

Improper installation, operational or environmental conditions.

ii) 

Inadequate ventilation in the area or competition for air from other household equipment or appliances.

iii)  Damage due to chemicals, dampness, condensation, or sulphur in the fuel supply lines which exceeds industry standards.

i)  This warranty does not cover glass, log breakage or damage to the unit while in transit.
j)  The Company does not allow anyone to extend, alter or modify this warranty and assumes no responsibility for direct, indirect or 

consequential damages caused by the unit. State or provincial laws where the 

fi

 rst purchaser or user resides may provide speci

fi

 c 

rights to extend this warranty and, if so, the Company’s sole obligation under this warranty is to provide labor and/or materials in 
accordance with those laws.

4. Discharge of Liability

After two (2) years from the date of purchase, the Company may, at its option, fully discharge all obligations under this warranty by 
paying to the 

fi

 rst purchaser/user the wholesale price of any defective parts.

5. No Other Warranty

All obligations to repair this unit are de

fi

 ned in this warranty. Some states or provinces may speci

fi

 cally mandate additional warranties 

on the part of manufacturers, but in the absence of such speci

fi

 c legislation, there is no other warranty or obligation expressed or 

implied.

Part or Component

Defect Covered

Maximum Warranty Period

Exterior steel casing

Corrosion

10 years

Glass

Loss of structural integrity

10 years

Cast iron parts

Corrosion

10 years

Firebox and heat exchanger

Corrosion (but not discoloration) causing 
loss of structural integrity

10 years

WARR

AN

TY

PR

OG

RAM

WARR

AN

TY

PR

OG

RAM

VA

LOR

CO M FO

R

T

VA

LOR

CO M FO

R

T

VA

LOR

CO M FO

R

T

If you have a problem with this unit, please contact your dealer or 
supplier immediately. Under no circumstances should you attempt 
to service the unit in any way by yourself. The warranties in 
paragraphs 1 and 2 are provided only to the 

fi

 rst purchaser/user of 

this unit, are not transferable and are subject to the conditions and 
limitations in paragraphs 3, 4 and 5. Please review the conditions 
and limitations carefully and strictly follow their requirements.

28

OWNER’S INFO

Содержание LEGEND 738BXN

Страница 1: ...tified kit is used This appliance is a domestic room heating appliance It must not be used for any other purposes such as drying clothes etc This appliance is suitable for installation in a bedroom or...

Страница 2: ...ry or damage the fireplace The information contained in this installation manual is believed to be correct at the time of printing Miles Industries Ltd reserves the right to change or modify any infor...

Страница 3: ...contact with a hot surface A physical barrier is strongly recommended if there are young children or at risk individuals in the house Install an approved after market safety gate to keep toddlers youn...

Страница 4: ...xisting Fireplace Preparation 11 Appliance Preparation 12 Supply Gas 14 Ignition Spark Check 15 Remote Control Preparation 16 Ceramic Bricks 17 Ceramic Logs 17 Window Refitting 19 Operation Check Aera...

Страница 5: ...Due to the high temperature the appliance should be LOCATED out of traffic areas and away from furniture and draperies Clothing or flammable material SHOULD NOT BE PLACED on or near the appliance Thi...

Страница 6: ...allations must be in accordance with the current ANSI Z223 1 and or local codes having jurisdiction Heating value of gas in some areas is reduced to compensate for elevation consult your local gas uti...

Страница 7: ...f the fire hearth or floor in front of the fire place may become very hot when place may become very hot when the fireplace heats Do not use the the fireplace heats Do not use the hearth as a seat or...

Страница 8: ...nnection Optional Outer Trim or Surround sold separately X Y Dimensions Cavity Check that masonry step does not interfere with install dimensions or vent pipe If mantel is combustible see section Clea...

Страница 9: ...nk warp crack peel and so on because of the heat produced by the fireplace Avoid placing candles and so on because of the heat produced by the fireplace Avoid placing candles paintings photos and othe...

Страница 10: ...an undistrubed airflow hits the outside vent terminal from any direction Check local codes for allowable vertical vent termination Vent Materials Use a 3 diameter aluminum flex liner approved for gas...

Страница 11: ...r stains once the 738BX insert is installed Consult with chimney sweep for information on how best to clean Existing Dampers Factory built zero clearance fireplaces will require the damper to be remov...

Страница 12: ...nsert Combustible Mantels Combustible mantel clearances must conform to those required for the original solid fuel fireplace into which the 738BX is being installed Window Removal The window is held i...

Страница 13: ...ing 4 tapping screws If the vent slider was removed from the firebox slide the firebox onto the vent slider in the cavity taking care not to damage the liner Make sure that the vent slider is pulled a...

Страница 14: ...stem at test pressures in excess of 1 2 psig 3 5 kPa The appliance must be isolated from the gas supply piping system by closing its equipment shut off valve during any pressure testing of the gas sup...

Страница 15: ...e unit are at the left end of the burner Push in the lighting knob and turn it counter clockwise through the IGN position to PILOT A spark should flash across from the pilot electrode to the pilot bur...

Страница 16: ...eft of the flame control button 3 Remove the remote control receiver lid 4 Fit four AA 1 5 V alkaline batteries Refit the lid 5 Place the remote control receiver on the base of the fireplace beside th...

Страница 17: ...s very carefully to avoid damaging the fragile material Install the logs as shown below Please note that the position of the Logs is critical to insure proper performance of the appliance 1 Spread the...

Страница 18: ...end on the pin located on the rear log Rest its wider end on the the crook in the front left log at an angle of approximately 30 degrees from the center line of the fireplace to allow for the flame t...

Страница 19: ...tion Settings Light the fire and allow the unit to warm up for 10 15 minutes to evaluate the flame picture Burners are equipped with an adjustable shutter to control primary aeration See the figures b...

Страница 20: ...the holder to the wall find a convenient location and use the hardware provided with the kit See the diagram below for required hardware and configurations Note that the holder can be installed at the...

Страница 21: ...emulsion type cleaner is recommended Use a soft damp cloth to apply the cleaner Dry the glass with a soft dry preferably cotton cloth Most paper towels and synthetic materials are abrasive to ceramic...

Страница 22: ...ilot Flame Soot or dust can be brushed from the ceramic logs and firebox walls using a soft brush Dust can also be removed from the burner using a soft brush after removing the ceramic logs When clean...

Страница 23: ...iance is equipped with a vent safety switch which when activated will turn off the burner and pilot if the vent is blocked disconnected or if there is excessive down draught If the safety switch is ac...

Страница 24: ...button sets the hour the button sets the minutes Set the time Note You must start setting the time while the F is flashing If it stops flashing go back to 1 3 The display shows C 24 hour or F 12 hour...

Страница 25: ...hile flashing push the buttons hour and minutes to set the time at which you want your fireplace to turn on in the morning 4 Press the TIMER button and hold it until P1 appears and flashes Let go Whil...

Страница 26: ...e of Outer Surrounds and Trims and Frets Optional Accessories 770ZCK Zero Clearance Kit 759EBL Enamel Liner 754RSK Rock Set Kit 760CBL Ceramic Black Liners fluted Conversion Kit optional 738PGK Conver...

Страница 27: ...tion above 2 Set the flame adjustment knob as far clockwise as possible 3 Turn the gas control knob clockwise to OFF NOTE The knob cannot be turned from PILOT to OFF unless it is pushed in partially D...

Страница 28: ...from other household equipment or appliances iii Damage due to chemicals dampness condensation or sulphur in the fuel supply lines which exceeds industry standards i This warranty does not cover glass...

Страница 29: ...for Pilot Pipe 420K385 21 Electrode 720A543 22 Electrode Retaining Nut 720A200 23 Thermocouple 4000061 24 Pilot Mount 4000138 25 Pipe Valve to Main Burner incl olive nuts 4000065 26 Burner Tray 400167...

Страница 30: ...Spare Parts NG LPG 1 2 3 4 5 6 7 9 10 11 12 13 14 15 16 24 27 26 25 30 28 29 49 50 51 52 48 41 42 43 44 45 46 47 12a NG LPG 11a 31 32 33 34 35 36 37 38 39 40 53 18 23 19 20 21 22 17 30 OWNER S INFO...

Страница 31: ...38BX NG natural gas LPG propane Serial No Front Trim code description e g 743FVI Double Door FenderFire Purchase date mm dd yyyy Home Owner Name Address City Province State Postal Code Zip Phone Email...

Страница 32: ...hut Thank you for choosing a Valor Product Postage needed Miles Industries Ltd 190 2255 Dollarton Highway North Vancouver BC V7H 3B1 Canada Fold here Online Warranty registration at www valorfireplace...

Отзывы: