
Venting Installation
IMPORTANT: This appliance’s venting system requires room air to be used
in the combustion process.
1. Rough-in one 3” diameter vent liner into the existing chimney
system from the roof. Be careful not to tear or damage the liner
in the process. Leave plenty of liner at the bottom to facilitate the
connection of the liner to the vent slider.
It is best to leave the top
termination until later.
2. a) Large cavity opening
Slide the appliance into the cavity.
b) Smaller cavity opening
Release the two screws retaining the vent slider to the front of the
fi
rebox.
Remove the slider from the
fi
rebox by sliding it towards the back of
the
fi
rebox.
3. Secure the liner to the collar on the vent slider using 4 tapping
screws.
If the vent slider was removed from the
fi
rebox, slide the
fi
rebox
onto the vent slider in the cavity taking care not to damage the liner.
Make sure that the vent slider is pulled all the way forward.
Secure the vent slider to the front of the
fi
rebox with two screws
removed earlier.
4. From the roof, pull the liner and
fi
t the
fl
ashing.
5. Fit the terminal cap. Secure with screws.
6. Seal the terminal and
fl
ashing from water penetration as required.
1
3
4
5
Appliance Preparation
option 2b
option 2a
6
WARNING
Failure to position the parts in
Failure to position the parts in
accordance with these diagrams or
accordance with these diagrams or
failure to use only parts speci
fi
cally
failure to use only parts speci
fi
cally
approved with this appliance
approved with this appliance
may result in property damage or
may result in property damage or
personal injury.
personal injury.
13
INSTALLATION