Lighting Instructions

Thermocouple 

  probe must be 

    in flame

LIGHTING INSTRUCTIONS

TO TURN OFF GAS TO APPLIANCE

FOR YOUR SAFETY READ BEFORE LIGHTING

WARNING: If you do not follow these instructions exactly, a fire or explosion may result 

causing property damage, personal injury or loss of life.

A. 

This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions 

exactly. To save energy, turn the pilot off when not using the appliance.

B. 

BEFORE LIGHTING

, smell all around the appliance area for gas. Be sure to smell next to the floor because 

some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

• 

Do not try to light any appliance.

•  Do not touch any electric switch; do not use any phone in your building.

• 

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

•  If you cannot reach your gas supplier, call the fire department.

C. 

Use only your hand to push in or turn the control knobs. Never use tools. If the controls will not push in or 

turn by hand, don’t try to repair them; call a qualified service technician. Force or attempted repair may result 

in a fire or explosion.

D. Do not use this appliance if any part has been under water. Immediately call a qualified service technician 

to inspect the appliance and to replace any part of the control system and any gas control, which has been 

under water.

1.  STOP! Read the safety information above.

2.  Set the flame adjustment knob as far clockwise 

 as possible*.

3.  Turn the gas control knob clockwise 

 to OFF.

NOTE: The knob cannot be turned from PILOT to OFF unless 

it is pushed in partially. Do not force.

4.  Wait five (5) minutes to clear out any gas, then, 

smell for gas, 

including near the floor. If you smell gas, STOP! Follow 

“B” in the safety information above. 

If you don’t smell gas, 

go to the next step.

5.  Find the pilot. It is at the left side of the firebox, viewed through slotted hole in front log.

6.  Push in and turn the gas control knob counter clockwise 

 until resistance is felt just before the IGN 

position.

7.  Keep pushed in for a few seconds to allow gas to flow then, keeping knob depressed, turn to PILOT to light 

pilot. Hold knob in for a further 5 seconds then release. The knob should pop back out. Pilot should remain 

lit. If pilot goes out, repeat steps 3 through 7. 

– If knob does not pop out when released, stop and immediately call your service technician or gas supplier. 

– If pilot lights but will not stay lit after several tries, turn the gas control knob to OFF and call your service 

technician or gas supplier.

8.  When pilot is lit, partially depress the knob and turn to ON position (Burner alight). 

Do not leave knob set between PILOT and ON.

9.  Set the flame height to desired setting*.

1. Set the flame adjustment knob as far clockwise 

 as possible*.

2. Push in the gas control knob slightly and turn clockwise 

 to OFF. Do not force.

* The flame height can be increased or decreased by depressing the remote control hand set button.

Flame

Adjustment

Knob

Gas

Control

Knob

Содержание HORIZON 535XAN

Страница 1: ...s appliance is suitable for installation in a bedroom or bed sitting room Manufactured by MILES INDUSTRIES LTD British Columbia Canada www valorfireplaces com Installation Operating Instructions Do no...

Страница 2: ...d by Dealer Name _______________________________________ Phone Number ______________________________________ Should you encounter an operational problem call your dealer immediately Do not try to repa...

Страница 3: ...Installations with Horizontal Termination Installing to Wall 23 Installations with Vertical Termination Through the Roof 25 Remote Control Installation 26 Gas Supply Installation 27 Aeration Setting C...

Страница 4: ...THER vent system or components MAY BE USED This gas fireplace and vent assembly MUST be vented directly to the outside and MUST NEVER be attached to a chimney serving a separate solid fuel burning app...

Страница 5: ...oor level b In the event that the requirements of this subdivision can not be met at the time of completion of installation the owner shall have a period of thirty 30 days to comply with the above req...

Страница 6: ...uirements shall be satisfied by the manufacturer 1 The referenced special venting system instructions shall be included with the appliance or equipment installation instructions and 2 The special vent...

Страница 7: ...primarily for post installation conversion in areas where natural gas was not available at the time of initial installation Venting options Direct vent installations solid piping A list of all approv...

Страница 8: ...Stand offs 7 180 mm From finished wall front to top vent 2 50 mm min From combustible framing to vent Stand offs 4 1 2 114 mm 1 1 2 38 mm 16 406 mm Dimensions Figure 1 Major dimensions clearances with...

Страница 9: ...nnel should install these appliances These appliances when installed must be electrically grounded in accordance with local codes or in the absence of local codes with the National Electrical Code ANS...

Страница 10: ...1 2 23 cm x 90 2 cm immediately above the opening area shown hatched in Figure 4 which must be constructed with non combustible materials such as cement board Wall Finish 29 3 4 to Wall Finish 38 3 4...

Страница 11: ...ble components The location requirements are shown in the table and graph below and figure 5 14 36 cm max combustible wall A B C D E F G H 1 0 2 3 4 5 6 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 FORBIDDE...

Страница 12: ...pipe lengths will be required A thimble kit may also be necessary See venting accessories list on pages 36 37 for allowable components Horizontal Termination Corner Location 45 Pipe Run See figures 5...

Страница 13: ...tructions supplied with the termination unit 2 The venting system for these appliances is considered to be a Special Venting System The rule in the Natural Gas and Propane Installation Code CAN CGA B1...

Страница 14: ...tical vent terminal cap or a low profile vertical termination Zero Clearance stand offs and shields supplied with the heater are not required for this application Flashing 2 x 3 liners 2 x 3 liners Co...

Страница 15: ...event condensation on window 12 30 D Vertical clearance to ventilated soffit located above the terminal within a horizontal distance of 2 feet 60 cm from the center line of the terminal 18 46 E Cleara...

Страница 16: ...4 Wood screws for fixing appliance to studding 1 Deluxe remote control 601SFB Standard Metal Front alternative 1 Upper louver unit 1 Lower louver unit 2 Side channels 2 Hinge studs 2 Hinge spacers 2 M...

Страница 17: ...r Louver Hinge Spacers Magnet Counterplates Hinge Studs Top Casting Bottom Casting Styrofoam Support Vent Pipe Terminal 12 Thread cutting Screws Wall Shields Wall Plates 8 Wall Plugs 8 Wood Screws Top...

Страница 18: ...and turn counterclockwise through the IGN position to PILOT A spark should flash across from the pilot electrode to the pilot shield 817VAK Pipe Adapter Fitting See figure 14 1 Fit the adapter 817VAK...

Страница 19: ...Instructions may vary as 556CLA may be installed on top or back of heater depending on heater model See Figure 14b 1 Remove blank plate and gasket to gain access to exhaust spigot Retain plate and goo...

Страница 20: ...tand offs and shield supplied with the heater are not required for the co linear application Support Angles Fitting See figure 17 The distance from the wall angles to the front face of the heater case...

Страница 21: ...as far as possible and tighten the screws over the restrictors To set the restrictors at minimum port opening slide the restrictors up as far as possible and tighten the screws Installations with Hor...

Страница 22: ...The top support angle should abut the cement board but is not fixed to the framing 3 Check the wall finish requirements with the homeowner If necessary adjust the position of the heater so that the di...

Страница 23: ...a 10 x 10 square If the wall is totally non combustible e g masonry block or concrete mark for a 7 circular hole In both cases the center of the hole should line up with the center line of the horizo...

Страница 24: ...mbustible fit wall thimbles Install as detailed in the manufacturer s instructions supplied with the pipes Sidewall vent terminations within 7 of grade require a terminal guard when used with a 551DVK...

Страница 25: ...a plumb from the roof to the small hole in the ceiling and mark the roof at this spot If rafters or other obstructions will prevent a vertical exit or if clear attic space is desired the roof outlet c...

Страница 26: ...ness plug Connect wires A with the L terminals to the connectors B on the control valve as shown below Please note that the L connectors are different sizes the smaller one fits to the lower connectio...

Страница 27: ...iance must be isolated from the gas supply piping system by closing its individual manual shut off valve during any pressure testing of the gas supply piping system at test pressures equal to or less...

Страница 28: ...the burner See figure 35 2 Place the rear log in position locating the two pins in the top of the wedge into the holes in the rear log See figure 36 3 Place the front log at the front of the firebox...

Страница 29: ...switch inside the appliance and the remote control hand unit See Lighting Instructions further on in this manual for full details Aeration adjustment As described on page 27 burner aeration is adjusta...

Страница 30: ...firebox sides See figure 45 2 Attach the top casting unit by hooking it over the four tabs at the firebox sides See figure 46 Additional Optional 3 or 4 Sided Trims 1 Slide a corner connection plate...

Страница 31: ...ft and unhook the two side channels See figure 51 Open the bottom louver it does not need to be removed Cast Iron Front Lift up and unhook the upper casting The bottom casting does not need to be remo...

Страница 32: ...l be helpful if the appliance serial number can also be quoted This is on the rating plate which is on a chained plate accessible by opening the bottom access panel The repair parts are shown in the s...

Страница 33: ...mperature Setting the temperature Use this setting when you come in and want to enjoy a specific temperature 1 Push the AUTO button until a number and F flash Let go 2 While it is still flashing push...

Страница 34: ...hold it until P1 appears and flashes Let go While flashing push the buttons hour and minutes to set the time at which you want your fireplace to turn on in the morning 4 Press the TIMER button and hol...

Страница 35: ...water 1 STOP Read the safety information above 2 Set the flame adjustment knob as far clockwise as possible 3 Turn the gas control knob clockwise to OFF NOTE The knob cannot be turned from PILOT to OF...

Страница 36: ...Vent Adapters Couplers Universal Adapter 3 Flex Coupler 2150 TM CFAA3 Co linear Flex Connector 46DVA ADF Co axial to Co linear Adapter 46DVA GCL TM 4CAA 556CLA Co linear to Co axial Adapter 46DVA GK...

Страница 37: ...46DVA FF TF 4F SV4F 559FSK Masonry Flashing TF 4MF Various Venting System Parts Wall Thimble 46DVA WT 4DT WT TM 4WT SV4RSM Storm Collar 46DVA SC 4DT SC TM SC SV4AC Decorative Plate 46DVA DC 4DT CS TM...

Страница 38: ...on for air from other household equipment or appliances iii Damage due to chemicals dampness condensation or sulphur in the fuel supply lines which exceeds industry standards i This warranty does not...

Отзывы: