10
10
Location
Framing
The framing dimensions are shown in Figure 4.
• A non-combustible hearth is not necessary in
front of this appliance.
• Note that the unit is installed at the framing
stage and fixed to framing using support
angles. See figures 17 and 21. Wall finish
(cement board above) is then installed over
the support angles up to the black frame on
the unit.
• Be aware of the area 9” x 35-1/2” (23 cm x
90.2 cm) immediately above the opening area
shown hatched in Figure 4 which must be
constructed with non-combustible materials
(such as cement board).
Wall Finish
29-3/4”
to Wall Finish
38-3/4”
to header
16” minimum
This is the framing
width. Wall finish
to 32-3/16” wide.
35-1/2”
This part of
wall MUST be
non-
combustible
(cement
board or
similar)
Figure 4 Framing
When the appliance is installed
directly on carpeting, tile or
other combustible material
other than wood flooring, the
appliance shall be installed on a
metal or wood panel extending
the full width and depth of the
appliance.