Handling heating installation
7.3.
Room thermostat
This device is not predicted for work without room thermostat. It
must be installed in reference room. Temperature control in all
rooms of the system is done via this remote controller. Radiators
in the reference room should not be equipped with thermostat
valves, or they always must be open. All radiators in other rooms
must be equipped with thermostat valves. Connecting room
thermostat is illustrated in the Section 5.4. When installing room
thermostat in reference room follow up with thermostat manufacturer
instructions.
7.4.
Heating interruption
With short-term interruption of heating the boiler temperature
must be reduced using thermostat regulator. In order to prevent
freezing of heating installation, boiler temperature must not be
lower than 5
˚C. With long-term interruption of heating, the boiler
must be out switched off. (
Section7.5).
7.5.
Switch off the boiler
When heating installation is not working, it could freeze with low
temperatures.
Protect heating installation against freezing
If there is risk of freezing, and boiler is off, empty the
installations.
Put main switcher on bottom panel in
ZERO position
(turn off).
When device is in long-term state of rest the heating pump can be
locked. To unlock the pump undertake the same procedure as
with air vent.
(
Section 4.6.2)
Содержание TK-24 12kW
Страница 20: ...Electric connection Figure 9 Electric scheme for boiler TK 24 nominal power of 6 kW...
Страница 21: ...Electric connection Figure 10 Electric scheme for boiler TK 24 nominal power of 9 kW and 12 kW...
Страница 22: ...Electric connection Figure 11 Electric scheme for boiler TK 24 nominal power of 18 kW 24 kW and 27 kW...
Страница 23: ...Electric connection Figure 12 Electric scheme for boiler TK 24 nominal power of 30 40 and 45 kW...
Страница 24: ...Electric connection Figure 13 Electric scheme for boiler TK 24 nominal power of 36 kW...