7.2
Regulatory elements
TK-24 40/45kW
TK-24 40kW
- Main switcher-Turning ON device and possibility
to turn on external circulation pump.
1
- Switcher 1
– Turning on heater
I
power group of 16 kW
via working and room thermostat,
(Signalling diode in it indicates heater group work).
2
- Switcher 2
– Turning on heater
II
power group of 16 kW
via working and room thermostat,
(Signalling diode in it indicates heater group work).
3
– Switcher 3 – Turning on heater
III
power group of 8 kW
via working and room thermostat,
(Signalling diode in it indicates heater work).
e
– Signal bulb (between switcher and switcher
1
)
signalling economic condition
– boiler works with
reduced power
4
– Working thermostat - for temperature selection in boiler.
Thermostat is three-grade, turns on/off heaters one by
one each 5°C. It eliminates shocks to electric network
and provides more accurate achievement and
maintenance of work temperature. Recommendation:
adjust boiler temperature within economic range of
50°C - 70°C
TK-24 45kW
- Main switcher-Turning ON device and possibility
to turn on external circulation pump.
1
- Switcher 1
– Turn on heater
I
power group of 18 kW
via working and room thermostat,
(Signalling diode in it indicates heater group work).
2
- Switcher 2
– Turn on heater
II
power group of 18 kW
via working and room thermostat,
(Signalling diode in it indicates heater group work).
3
– Switcher 3 – Turn on heater
III
power group of 9kW
via working and room thermostat,
(Signalling diode in it indicates heater group work).
e
- Signalling diode (between switcher
and
1
)
signalling economic condition
– boiler works with
reduced power
4
– Working thermostat – for temperature selection in
boiler. Thermostat is three-grade, turns on/off heaters
one by one each 5°C. It eliminates shocks to electric
network and provides more accurate achievement
and maintenance of work temperature.
Recommendation: adjust boiler temperature within
economic range of 50°C - 70°C
Power selection
TK-24
40/45kW
by combination of control panel
switches
Work instruction for
TK-24 40/45kW
4
Содержание TK-24 12kW
Страница 20: ...Electric connection Figure 9 Electric scheme for boiler TK 24 nominal power of 6 kW...
Страница 21: ...Electric connection Figure 10 Electric scheme for boiler TK 24 nominal power of 9 kW and 12 kW...
Страница 22: ...Electric connection Figure 11 Electric scheme for boiler TK 24 nominal power of 18 kW 24 kW and 27 kW...
Страница 23: ...Electric connection Figure 12 Electric scheme for boiler TK 24 nominal power of 30 40 and 45 kW...
Страница 24: ...Electric connection Figure 13 Electric scheme for boiler TK 24 nominal power of 36 kW...