User’s manual for Repeater MRx01B Power
M0079A1A.doc
Id.-No. 151775
Page 56
10-March-00
figure 8-12 Position of feedforward amplifier reset board
Remove the ready made cable which is plugged to the 15 pole SUB-D connector of the reset
board. Unscrew the screw clip first.
Unscrew the 6 socket head cap screws.
The SMA connectors can be removed only
after
dismounting the amplifier.
The position of the feedforward amplifiers is illustrated in figure 8-13 Position of feedforward
amplifiers.
Reset board