![MIKOM MR301B Power Скачать руководство пользователя страница 52](http://html1.mh-extra.com/html/mikom/mr301b-power/mr301b-power_user-manual_1793935052.webp)
User’s manual for Repeater MRx01B Power
M0079A1A.doc
Id.-No. 151775
Page 52
10-March-00
For the exchange of a conversion module or the installation
of a new conversion module, the slave address of the synthesizer
has to be set. This can be done by means of hex-coded
rotary switches mounted on the lower side of the modules
Hex-coded rotary switch for UL
Hex-coded rotary switch for DL
The synthesizer address must be set like shown
in the following table:
Conversion module
Address
UL
DL
Channel one
0
1
Channel two
2
3
Channel three
4
5
Channel four
6
7
figure 8-4 Position of hex-coded
rotary switches
table 8-5 Address of synthesizer
Conversion modules with variable bandwidth have four rotary switches. The synthesizer
address must be set like shown in the following table:
Filter 1
Filter 2
UL
DL
UL
DL
Channl one
0
1
0
1
Channel two
2
3
2
3
Channel three
4
5
4
5
Channel four
6
7
6
7
table 8-6 Adress of synthesizer, conversion modules
with variable bandwidth
figure 8-7 Position of hex-coded rotary switches
at variable bandwidth module
Further instructions for band selective modules with variable bandwith can be found in a
separate document.