![MIKOM MR301B Power Скачать руководство пользователя страница 50](http://html1.mh-extra.com/html/mikom/mr301b-power/mr301b-power_user-manual_1793935050.webp)
User’s manual for Repeater MRx01B Power
M0079A1A.doc
Id.-No. 151775
Page 50
10-March-00
8.6 Replacement of the duplexers
This description is valid for the one channel configuration of the Repeater only. For different
configurations refer to the assembly guide for the Repeater.
Remove the semi-rigid cables which connect the UL output and the DL output with the
feedforward amplifier by loosing the SMA connectors. Use a torque wrench. Then remove the
semi-rigid cables from the conversion modules. (BTS side marked with a red spot).
It is recommended not to remove the amplifier which is mounted on the backside of the
duplexer. A new duplexer will be delivered with a premounted amplifier.
Unscrew the four counter sunk screws M3 at the connector panel of the Repeater. See figure
5-6 Connector panel layout.
For mounting the duplexers proceed in reverse order.
The cables have to be connected like shown in figure 9-4 Cabling of one channel Repeater.
8.7 Replacement of conversion modules
To remove the conversion modules, disconnect the SMA connectors by means of a torque
wrench.
If the Repeater is equipped with iDEN channel modules, the external filter on top of the
modules must be dismounted beforehands. The external filter box covers two of the socket
head cap screws the iDEN module is fixed with.