MM262 Installation Instructions
12
Closed Position Stop Plate mounted
on the SECOND GATE
Closed Position Stop Plate
Low Profile
Ground Stop
in Near the Center of Driveway
FACING VIEW
SIDE VIEW
Mount Vertically
Closed Position
Stop Plate
Low Profile Ground Stop
Closed Position
Stop Plate
Step 4
Using appropriate hardware for your type of gate, attach the vertical
closed position stop plate to the SECOND gate frame at the point
where it will come in contact with the low profile ground stop. Do not
tighten it completely at this time. You must slide the closed position
stop plate toward the low profile ground stop until they touch. Once
you have moved the stop plate to the correct position, tighten its
hardware completely.
Step 5
Return the gates to their open positions and
reattach the gate openers to the gates.
Control Box
1.
KEE
P CLE
AR! G
ate may mo
ve at a
ny tim
e.
2.
Do not allow c
hildre
n to op
erate
gate or
play in gat
e area.
3.
This gate is
for vehic
les on
ly. P
edest
rian
s
must
use a se
parate
entra
nce.
Moving Ga
te Can
Ca
use
Injury O
r Dea
th
WARNING
!
Control Box
Piece of Wood
for Mounting
Mount the Control Box
Step 1
Mount the control box using the screws
(provided) or another secure mounting
method. The control box must be mounted
at least 3 feet above the ground to protect it
from rain splash, snow, etc., and at least 3 feet
from an AC power source to prevent electrical
interference.
Step 2
Remove the control box cover by removing the
four (4) screws.
Step 3
Attach antenna to control box cover. First,
remove the Phillips screw (labeled ANT) from
the control box cover. Place one end of the
antenna coil over the antenna plug (antenna
wire will fit into groove). Tighten the Phillips
screw to secure antenna.