16
CONTROL PANEL
Digital display
The control panel is equipped
with a display showing the
welding current. During standby the pre-set
welding current is displayed, while the actual
welding current is shown during welding.
Disconnection error
The overheating indicator is
illuminated if welding is interrupted due to
overheating of the machine. When the
situation is back to normal, the machine will
reconnect automatically. Therefore, welding
cables must be placed so the risk of un-
intended establishment of the arc is avoided
during reconnection.
Welding voltage
The welding voltage indicator is
illuminated for reasons of safety and in order
to show if there is voltage at the output taps or
electrode.
Welding current
Welding current is adjusted by
means of this control knob. The
current is adjustable from 10 A
to 180A(MMA)/200A(TIG). The adjusted value
is shown in the display.
Function switch
This switch is used for
selection of MMA or TIG
welding, ignition method in
TIG welding and two-times or four-times
ignition in TIG welding.
This symbol indicates MMA welding.
This symbol indicates TIG welding.
Two-stroke HF-ignition:
This symbol means contact-free
striking. The arc is established in the following
way:
1) The torch is placed so that the Tungsten
electrode is quite close to the welding
spot (1 or 2 mm).
2) The torch trigger is activated and must be
kept pressed down. The high voltage
generator of the machine will produce a
voltage impulse that ignites the arc. The
welding process has started. The welding
process will stop when the torch trigger is
deactivated. The arc will extinguish after
the period of slope-down time.