![Miele T 15 Series Скачать руководство пользователя страница 38](http://html.mh-extra.com/html/miele/t-15-series/t-15-series_technical-information_235115038.webp)
Technical Information
38
T 15xx Dryers
The “Anti-crease” LED is FLASHING - Fault stored. Proceed to “Access”
steps below.
Access (retrieval):
1. Access the service mode. See Section 6.1.2.
2. Turn the selector switch to “Woolens”.
3. Press the
Start
button.
4. Note the illuminated LEDs.
5. Refer to Table 6-3 to determine the stored fault.
6. Switch the appliance off.
7. Perform the necessary service steps to rectify the cause of the fault, then
proceed to “Delete a Stored Fault Code” below.
LED(s) Lit Steadily
Component
Rotary iron
Fan NTC open circuit
Hand iron
NTC at heater bank open circuit
Normal
NTC at heater bank short circuit
Rotary iron & Hand iron
Fan NTC short circuit
Normal and Rotary iron
Maximum drying time (180 minutes) exceeded
Table 6-3:
T 1576 Fault Codes
Delete a stored fault code:
1. Access the service mode. See Section 6.1.2.
2. Turn the selector switch to “Woolens”.
3. Press the
Start
button.
4. Press and hold the
Gentle
button.
5. Press the
Start
button.
6. Release the
Gentle
button. The appropriate LED turns off.
7. Switch the appliance off.
6.3
Programming Mode (T 1576 Only)
Accessing:
1. Switch the appliance off.
2. Turn the program selector switch to 12 o’clock.
3. Press and hold the
Gentle
and
Buzzer
buttons.
4. Switch the appliance on.
5. Release the buttons.
Acknowledgement indicator:
The “Drying” and “Cooling down” LEDs flash to indicate that programming mode
is active.
Navigation:
1. Turn the program selector switch to the desired position; press
Start
to
activate the function.
2. The programmed option is indicated by the status of the “Rotary iron” LED.