Filter change indicator (see fig. 32)
Certain models are equipped with a
filter change indicator to show you
when to change the Active Air Clean
b
or Active HEPA
c
filter.
The indicator and the reset button will
light after approximately 50 hours of
operation, which is equivalent to an
average of one year of use. Once the
indicator light comes on, you can still
continue to use the vacuum cleaner.
However, the filter performance and
suction power will be reduced.
If you use the Air Clean
a
exhaust filter
instead, lighting of the filter change
indicator and reset button can be
disregarded as you simply replace the
Air Clean filter every time you open a
new box of Miele filter bags. The
indicator lights turn off when the reset
button is pressed.
How to replace the Air Clean exhaust
filter? (see fig. 33 + 34)
Make sure that only one exhaust
filter is inserted in the frame.
^
Open the dust compartment lid.
^
Squeeze the release for the filter
frame and open until it clicks.
^
Grasp one of the two clean corners
(see arrow) to remove the used Air
Clean exhaust filter.
^
Insert a new Air Clean exhaust filter.
But if you want to install an Active Air
Clean or Active HEPA filter, you must
heed the section "Maintenance and
care - Exchanging exhaust filters".
^
Close the filter frame.
^
Close the dust compartment lid until
it clicks into place.
How do I change the Active Air Clean
or the Active HEPA exhaust filter?
(see fig. 35 + 36)
Make sure that only one exhaust
filter is inserted in the frame.
^
Open the dust compartment lid.
^
Lift the exhaust filter and remove it.
^
Install the new Active Air Clean or
Active HEPA exhaust filter and press
it downwards.
If you want to install an Air Clean
exhaust filter, you must adhere to
the section "Maintenance and
care - Exchanging exhaust filters".
^
Close the dust compartment lid until
it clicks into place.
Resetting the filter change indicator
If your vacuum cleaner has a filter
change indicator (see fig. 32), it must
be pressed each time the exhaust filter
is changed. To do this, the vacuum
cleaner must be plugged in.
^
Press the reset button.
The filter change indicator and the reset
button will go out and return to its initial
position.
The indicator is only reset if pressed
while lit. If the indicator is pressed
while not lit, it will not be reset.
en
17