PWM 908
en-US
= standard,
= optional, + = only on request, - not available
8
11 282 580/00
Technical data
PWM 908 DV
PWM 908 DP
Drum volume
gal (l)
19.3 (73)
19.3 (73)
Capacity
lb (kg)
17.6 (8.0)
17.6 (8.0)
Door opening diameter
inch (mm)
11 13/16" (300)
11 13/16" (300)
Max. spin speed
rpm
1,600
1,600
g-factor
704
704
Residual moisture (standard load according to DIN 60456)
%
48
48
E l e c t r i c a l c o n n e c t i o n ( E L )
Standard voltage
2N AC 400 V
2N AC 400 V
Frequency
Hz
50
50
Total rated load
kW
5.5
5.5
Fuse rating (B trip rating according to EN 60898)
A
2 x 16
2 x 16
Power cord min. cross-section
mm²
4 x 1.5
4 x 1.5
Wire without plug
Wire length
inch (mm)
78 3/4" (2,000)
78 3/4" (2,000)
Alternative voltage (convertible by Technical Service)
1N AC 230 V
1N AC 230 V
Total rated load
kW
2.85
2.85
Fuse rating (B trip rating according to EN 60898)
A
1 x 16
1 x 16
Power cord min. cross-section
mm²
3 x 1.5
3 x 1.5
Non-standard voltages MAR 400/440/480 (Marine)
-
3 AC 400/440/480V
Frequency
Hz
-
50/60
Total rated load
kW
-
3.6/4.23/5.0
Fuse rating (B trip rating according to EN 60898)
A
-
3 x 16
Power cord min. cross-section
mm²
-
4 x 1.5
Wire without plug
-
Wire length
inch (mm)
-
78 3/4" (2,000)
Non-standard voltage MAR 230 (Marine)
-
3 AC 230 V
Frequency
Hz
-
50/60
Total rated load
kW
-
4.4
Fuse rating (B trip rating according to EN 60898)
A
-
3 x 16
Power cord min. cross-section
mm²
-
4 x 1.5
Wire without plug
-
Wire length
inch (mm)
-
78 3/4" (2,000)
Non-standard voltage MAR 400 (Marine)
-
2N AC 400 V
Frequency
Hz
-
50/60
Total rated load
kW
-
5.5
Fuse rating (B trip rating according to EN 60898)
A
-
2 x 16
Power cord min. cross-section
mm²
-
3 x 1.5
Wire without plug
-
Wire length
inch (mm)
-
78 3/4" (2,000)
Non-standard voltage MAR 208-240 (Marine)
-
2 AC 208-240 V
Frequency
Hz
-
60
Total rated load
kW
-
4.0
– 5.2
Fuse rating (B trip rating according to EN 60898)
A
-
2 x 30
Power cord min. cross-section
-
3 x AWG10
Wire with plug
-
Wire length
inch (mm)
-
78 3/4" (2,000)