Installationsplan / Installation plan: PW 6163 EL/D
Datum / Date: 16.03.2011
Seite / Page: 9
Technical datasheet
Washer-extractor:
Heating:
PW 6163
Electric /
Steam
Legend:
Abbreviations in bold type:
Connection required
en-GB
Abbreviations in circle with dashes:
Connection optional or required depending on model
version
Optional extras:
BWS
Conversion kit
Steam and
foam discharge
Vapour discharge on site (int. diameter)
mm
110 [DN 100
connection]
Foam discharge connection on site (ext. diameter)
mm
110 [DN 100]
Drainage must be provided for condensate.
Alternatively, the foam pipe can be passed through
the machine to the machine drain.
ISA
Integrated
foam line
Pipework
mm
50 [DN 50
connection]
Opening in machine casing (diameter)
mm
63.5
MSG
Additional Miele
fan
Standard voltage
V
1N AC 230
Frequency
Hz
50
Rated load
kW
0.03
Max. air throughput
m³/h
150
Max. pressure gradient
Pa
170
Sound power level
dB (A)
60
DAV
Steam
connection
valve
The following electric steam valve and pneumatic
steam valve can be ordered separately.
Electric steam valve (ELD 01)
Regulatable steam pressure
kPa
200 - 1000
Connection gauge
Inch
½“
Voltage
V
1N AC 230
Pneumatic steam valve (PND)
Regulatable steam pressure
kPa
0 - 1000
Connection gauge
Inch
½“
The steam connection valve to regulate the steam
supply must be provided on site.
UM
Miele plinth
Box plinth
Height
mm
170
Width
mm
1110
Depth
mm
870
WI
Weighing
system
Plinth with integrated weighing system
Height
mm
170
Width
mm
1110
Depth
mm
870
Machine should not be subject to external loads or
weights when using weighing system.
Temporary or static loads on casing may prevent the
calibration of the weighing cells and impair the proper
functioning of the weighing system.
All supply connections including steam supply must