Installationsplan / Installation plan: PW 6163 EL/D
Datum / Date: 16.03.2011
Seite / Page: 11
Cold water
(Soft water)
Max. temperature
°C
70
Min. flow pressure
kPa
100
Max. pressure
kPa
1000
Volume flow necessary
l/min
16
Special version, unit without detergent dispenser.
Volume flow necessary
l/min
20
On-site connection thread according to DIN 44 991
Inch
¾" external thread
Length of connection hose
mm
1500
(supplied: 1 connection hose)
Water requirements with standard connection to hot
water in 60°C programme ( average value)
l/h
not yet available
In absence of hot water supply, connect hose to cold
water supply!
Cold water
(Hard water)
Min. flow pressure
kPa
100
Max. pressure
kPa
1000
Volume flow necessary
l/min
32
On-site connection thread according to DIN 44 991
Inch
1" external thread
Length of connection hose
mm
1500
(supplied: 2 connection hoses + Y piece)
Water requirements with standard connection to hot
water in 60°C programme ( average value)
l/h
not yet available
In absence of hard water supply, connect hose to cold
water supply!
Cold water
Liquid
dispensing
(Optional)
Min. flow pressure
kPa
100
Max. pressure
kPa
1000
On-site connection thread according to DIN 44 991
Inch
¾" external thread
Length of connection hose
(supplied) 1 connection hose)
mm
1500
Drainage via
dump valve
Max. temperature
°C
95
Machine-side drain connection (ext. diameter)
mm
75 [DN 70]
On-site drain (int. diameter)
mm
75 [DN 70
connection]
Max. transient throughput
l/min
200
Vented manifold required.
Drain manifolds serving several machines must be of
sufficient cross-section.
Machine vent
Machine-side connection for Miele vapour and foam
venting kit.
Machine-side
vent line
On-site vapour vent for connection to Miele vapour
and foam venting kit or additional fan.
Equipotential
bonding
Connection with male thread
mm
10 × 35
with washers and nut.
M
10
If necessary, equipotential bonding with good
galvanic contact
must be provided in accordance with all appropriate
national and local regulations.
Fittings
(supplied)
Without plinth
4 × screws DIN 571 (Ø × length)
mm
12 × 90
4 × rawl plugs (Ø × length)
mm
16 × 80
Machine must be bolted to the floor!
Fixing materials for a floating screed floor are to be
provided on site.
Miele plinth / Weighing system plinth
4 × screws DIN 571 (Ø × length)
mm
12 × 90
4 × rawl plugs (Ø × length)
mm
16 × 80
Machine must be bolted to the floor!
Fixing materials for a floating screed floor are to be
provided on site.
MEL