Technisches Datenblatt / Technical datasheet: PW 6207 D
Datum / Date: 24.04.2013
Seite / Page:
9
Steam
connection
Steam pressure
kPa
600 - 1000
Indirect
Boiling point
°C
152 - 184
Mass flow (max. delivery)
kg/h
58
Heater rating
kW
32
On-site threaded union
Inch
½" female thread
Steam valve, filter, non-return valve and steam shut-off valve
must be provided on site.
Steam valve supply lead length
mm
500
The supply lead for the electric steam valve is included.
The steam valve should be installed close to the steam
connection.
Installation instructions for steam-heated washer-extractors
apply throughout.
Condensate
connection
On-site threaded union
Inch
½" female thread
A shut-off device and condensate trap must be provided on
site.
The condensate separator must be installed such that when
the system is not operating, the heater bank is completely
emptied. This means that no condensate may remain in the
heater bank. The use of an inverted bucket condensate trap
is recommended.
Cold water
(softened water)
Min. water pressure/flow pressure
kPa
100
Max. water pressure/flow pressure
kPa
1000
Flow rate, max.
l/min
26
Max. throughput (if hot and raw water supply is not available)
l/min
42
2 connection hoses with ¾" threaded union incl. Y-piece (¾" /
1") supplied.
On-site threaded union in accordance with DIN 44991 (flat
sealing)
Inch
1" male thread
Connection hose length
mm
1500
Average water requirements for a standard 60°C Cottons
programme calculated using cold, hot and hard water
supplies.
l/h
approx. 124
In the absence of a hot water supply, add sufficient water to
reach the required amount.
If connecting to raw water, subtract water requirement from
cold water.
Hot water
(softened water)
Max. water intake temperature
°C
70
Min. water pressure/flow pressure
kPa
100
Max. water pressure/flow pressure
kPa
1000
Max. flow rate
l/min
16
1 inlet hose with ¾" threaded union provided.
On-site threaded union in accordance with DIN 44991 (flat
sealing)
Inch
¾" male thread
Connection hose length
mm
1500
Average water requirements for a standard 60°C Cottons
programme calculated using cold, hot and hard water
supplies.
l/h
Approx. 108
If no hot water supply available, connect hot water hose to
cold water supply!
Cold water
Raw water
Min. water pressure/flow pressure
kPa
100
Max. water pressure/flow pressure
kPa
1000
Flow rate, max.
l/min
32
2 connection hoses with ¾" threaded union including Y-piece
(¾" / 1") included in optional kit.
On-site threaded union in accordance with DIN 44991 (flat
sealing)
Inch
1" male thread
Connection hose length
mm
1500
Average water consumption in standard programme (60°
Cottons) when connected to cold, hot and raw water supplies.
l/h
74