Technisches Datenblatt / Technical datasheet: PW 6207 D 

Datum / Date: 24.04.2013 

  Seite / Page: 

9

 

 

 

 

Steam 
connection 

Steam pressure 

kPa 

600 - 1000 

Indirect 

Boiling point 

°C 

152 - 184 

 

Mass flow (max. delivery) 

kg/h 

58 

 

 

Heater rating 

kW 

32 

 

 

On-site threaded union 

Inch 

½" female thread 

 

 

Steam valve, filter, non-return valve and steam shut-off valve 
must be provided on site. 

 

 

 

 

Steam valve supply lead length 

mm 

500 

 

 

The supply lead for the electric steam valve is included. 

 

 

 

 

The steam valve should be installed close to the steam 
connection. 

 

 

 

 

Installation instructions for steam-heated washer-extractors 
apply throughout. 

 

 

 

Condensate 

connection 

On-site threaded union

 

Inch 

½" female thread

 

A shut-off device and condensate trap must be provided on 
site.

 

 

 

 

 

The condensate separator must be installed such that when 
the system is not operating, the heater bank is completely 
emptied. This means that no condensate may remain in the 
heater bank. The use of an inverted bucket condensate trap 
is recommended. 

 

 

 

Cold water 

(softened water) 

Min. water pressure/flow pressure 

kPa 

100 

Max. water pressure/flow pressure 

kPa 

1000 

Flow rate, max. 

l/min 

26 

 

 

Max. throughput (if hot and raw water supply is not available) 

l/min 

42 

 

 

2 connection hoses with ¾" threaded union incl. Y-piece (¾" / 
1") supplied. 

 

 

 

 

On-site threaded union in accordance with DIN 44991 (flat 
sealing) 

Inch 

1" male thread 

 

 

Connection hose length 

mm 

1500 

 

 

Average water requirements for a standard 60°C Cottons 
programme calculated using cold, hot and hard water 
supplies. 

l/h 

approx. 124 

 

 

In the absence of a hot water supply, add sufficient water to 
reach the required amount. 

 

 

 

 

If connecting to raw water, subtract water requirement from 
cold water. 

 

 

 

Hot water 

(softened water) 

Max. water intake temperature 

°C 

70 

Min. water pressure/flow pressure 

kPa 

100 

Max. water pressure/flow pressure 

kPa 

1000 

 

 

Max. flow rate 

l/min 

16 

 

 

1 inlet hose with ¾" threaded union provided. 

 

 

 

 

On-site threaded union in accordance with DIN 44991 (flat 
sealing) 

Inch 

¾" male thread 

 

 

Connection hose length 

mm 

1500 

 

 

Average water requirements for a standard 60°C Cottons 
programme calculated using cold, hot and hard water 
supplies. 

l/h 

Approx. 108 

 

 

If no hot water supply available, connect hot water hose to 
cold water supply! 

 

 

 

Cold water 
Raw water 

Min. water pressure/flow pressure 

kPa 

100 

Max. water pressure/flow pressure 

kPa 

1000 

Flow rate, max. 

l/min 

32 

 

 

2 connection hoses with ¾" threaded union including Y-piece 
(¾" / 1") included in optional kit. 

 

 

 

 

On-site threaded union in accordance with DIN 44991 (flat 
sealing) 

Inch 

1" male thread 

 

 

Connection hose length 

mm 

1500 

 

 

Average water consumption in standard programme (60° 
Cottons) when connected to cold, hot and raw water supplies. 

l/h 

74 

 
 

 

Содержание PW 6137 D

Страница 1: ...06 15 M Nr 10 303 290 01 Installation plan Washer extractor PW 6207 D en GB ...

Страница 2: ...M Nr 10 303 290 01 2 ...

Страница 3: ......

Страница 4: ......

Страница 5: ......

Страница 6: ......

Страница 7: ...mm 240 Width mm 920 Depth mm 1019 BS Concrete platform Recommended height mm 240 Minimum height mm 100 Plinth width min mm 920 Min plinth depth mm 1050 DAV Steam connection valve The steam connection valve to regulate the steam supply must be provided on site The following valves can be ordered separately as electric steam valves or as pneumatic steam valves Electric steam valve ELD 01 Regulatable...

Страница 8: ... is the responsibility of a qualified electrician The machine can be either hard wired or connected via a socket in compliance with IEC 60309 1 Wall socket or mains isolator must be accessible after installation It is always recommended to make electrical connection via a plug and socket so that electrical safety checks e g during repair or service work can be carried out easily If it is necessary...

Страница 9: ...n incl Y piece 1 supplied On site threaded union in accordance with DIN 44991 flat sealing Inch 1 male thread Connection hose length mm 1500 Average water requirements for a standard 60 C Cottons programme calculated using cold hot and hard water supplies l h approx 124 In the absence of a hot water supply add sufficient water to reach the required amount If connecting to raw water subtract water ...

Страница 10: ...ately anchored to the floor Fastening material included with unit 2 angled brackets from transport strut 2 wood screws DIN 571 Ø length mm 8 x 80 2 wall plugs Ø length mm 12 x 60 The installation surface must be sufficiently stable and solid The fastening material provided is designed for securing the machine to a concrete floor only Fasteners for other floor types must be provided on site On conc...

Страница 11: ...of lid mm 400 Net weight kg 495 Max floor load in operation N 6076 Max static floor load N 5543 Max dynamic floor load N 533 Max drum rotation frequency Hz 18 3 Average heat dissipation to installation site depending on ambient temperature and programme selected W N A Installation should only be performed by qualified fitters in accordance with valid regulations relevant standards and health and s...

Отзывы: